{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-23T01:58:15.575","vulnerabilities":[{"cve":{"id":"CVE-2020-10642","sourceIdentifier":"ics-cert@hq.dhs.gov","published":"2020-04-13T19:15:11.000","lastModified":"2024-11-21T04:55:45.520","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"In Rockwell Automation RSLinx Classic versions 4.11.00 and prior, an authenticated local attacker could modify a registry key, which could lead to the execution of malicious code using system privileges when opening RSLinx Classic."},{"lang":"es","value":"En Rockwell Automation RSLinx Classic versiones 4.11.00 y anteriores, un atacante local autenticado podría modificar una clave de registro, lo que podría conllevar a una ejecución de código malicioso usando privilegios system al abrir RSLinx Classic"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:C/I:C/A:C","baseScore":7.2,"accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":3.9,"impactScore":10.0,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-732"}]},{"source":"nvd@nist.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-732"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:rockwellautomation:rslinx_classic:*:*:*:*:*:*:*:*","versionEndIncluding":"4.11.00","matchCriteriaId":"4F6780E2-AB8D-4860-812F-CBE82A94EF0D"}]}]}],"references":[{"url":"https://www.us-cert.gov/ics/advisories/icsa-20-100-01","source":"ics-cert@hq.dhs.gov","tags":["Third Party Advisory","US Government Resource"]},{"url":"https://www.us-cert.gov/ics/advisories/icsa-20-100-01","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"]}]}}]}