{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-15T03:18:46.082","vulnerabilities":[{"cve":{"id":"CVE-2020-10641","sourceIdentifier":"ics-cert@hq.dhs.gov","published":"2020-04-28T19:15:12.207","lastModified":"2024-11-21T04:55:45.403","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"An unprotected logging route may allow an attacker to write endless log statements into the database without space limits or authentication. This results in consuming the entire available hard-disk space on the Ignition 8 Gateway (versions prior to 8.0.10), causing a denial-of-service condition."},{"lang":"es","value":"Una ruta de registro no protegida puede permitir a un atacante escribir sentencias de registro interminables en la base de datos sin límites de espacio o autenticación. Esto resulta en consumir todo el espacio disponible en el disco duro en el Ignition 8 Gateway (versiones anteriores a 8.0.10), causando una condición de denegación de servicio."}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:N/A:P","baseScore":5.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":10.0,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-284"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-306"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:inductiveautomation:ignition_gateway:*:*:*:*:*:*:*:*","versionStartIncluding":"8.0","versionEndExcluding":"8.0.10","matchCriteriaId":"4D54DBE1-0273-41EF-AC65-611E74CD00FA"}]}]}],"references":[{"url":"https://www.us-cert.gov/ics/advisories/icsa-20-112-01","source":"ics-cert@hq.dhs.gov","tags":["Third Party Advisory","US Government Resource"]},{"url":"https://www.us-cert.gov/ics/advisories/icsa-20-112-01","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"]}]}}]}