{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-24T19:54:28.305","vulnerabilities":[{"cve":{"id":"CVE-2019-9569","sourceIdentifier":"cve@mitre.org","published":"2019-08-26T20:15:10.127","lastModified":"2026-06-17T02:43:58.080","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Buffer Overflow in dactetra in Delta Controls enteliBUS Manager V3.40_B-571848 allows remote unauthenticated users to execute arbitrary code and possibly cause a denial of service via unspecified vectors."},{"lang":"es","value":"El desbordamiento de búfer en dactetra en Delta Controls enteliBUS Manager V3.40_B-571848 permite a los usuarios remotos no autenticados ejecutar código arbitrario y posiblemente causar una denegación de servicio a través de vectores no especificados."}],"affected":[{"source":"cve@mitre.org","affectedData":[{"vendor":"n/a","product":"n/a","versions":[{"version":"n/a","status":"affected"}]}]}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","baseScore":7.5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"HIGH","exploitabilityScore":10.0,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-787"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:deltacontrols:entelibus_firmware:3.40_b-571848:*:*:*:*:*:*:*","matchCriteriaId":"D47FDA03-D772-4A29-B6C7-849587E469E9"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:deltacontrols:entelibus:-:*:*:*:*:*:*:*","matchCriteriaId":"EA176855-741E-4D66-98ED-3E7C8228FF22"}]}]}],"references":[{"url":"https://securingtomorrow.mcafee.com/other-blogs/mcafee-labs/hvacking-understanding-the-delta-between-security-and-reality/","source":"cve@mitre.org","tags":["Exploit","Third Party Advisory"]},{"url":"https://www.deltacontrols.com/products/hvac-controls/central-plant-controllers/entelibus","source":"cve@mitre.org","tags":["Product"]},{"url":"https://securingtomorrow.mcafee.com/other-blogs/mcafee-labs/hvacking-understanding-the-delta-between-security-and-reality/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Exploit","Third Party Advisory"]},{"url":"https://www.deltacontrols.com/products/hvac-controls/central-plant-controllers/entelibus","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Product"]}]}}]}