{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-20T13:46:48.889","vulnerabilities":[{"cve":{"id":"CVE-2019-6835","sourceIdentifier":"cybersecurity@se.com","published":"2019-09-17T20:15:12.530","lastModified":"2024-11-21T04:47:14.870","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A Cross-Site Scripting (XSS) CWE-79 vulnerability exists in U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), which could allow an attacker to inject client-side script when a user visits a web page."},{"lang":"es","value":"Existe una vulnerabilidad de tipo Cross-Site Scripting (XSS) CWE-79 en U.motion Server (MEG6501-0001 - U.motion KNX server, MEG6501-0002 - U.motion KNX Server Plus, MEG6260-0410 - U.motion KNX Server Plus, Touch 10, MEG6260-0415 - U.motion KNX Server Plus, Touch 15), que podría permitir a un atacante inyectar script del lado del cliente cuando un usuario visita una página web."}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N","baseScore":5.4,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":2.3,"impactScore":2.7}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:S/C:N/I:P/A:N","baseScore":3.5,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"SINGLE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE"},"baseSeverity":"LOW","exploitabilityScore":6.8,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-79"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-79"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:meg6501-0001_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.3.7","matchCriteriaId":"716CA99C-BB90-422B-9EAD-A066D48DE1E8"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:o:schneider-electric:meg6501-0001:-:*:*:*:*:*:*:*","matchCriteriaId":"DB83620B-3DE0-405A-92F7-99E1B2150E75"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:meg6501-0002_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.3.7","matchCriteriaId":"0D2468D0-D50D-4843-8620-CAD0F40E9329"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:o:schneider-electric:meg6501-0002:-:*:*:*:*:*:*:*","matchCriteriaId":"CC12A2AA-C006-4606-981A-FE54C1EA3B3F"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:meg6260-0410_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.3.7","matchCriteriaId":"DB404224-29BF-4440-963C-0734A51CE6D1"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:o:schneider-electric:meg6260-0410:-:*:*:*:*:*:*:*","matchCriteriaId":"0936523A-B9CB-451E-BF5E-9E7020DA96A2"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:meg6260-0415_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.3.7","matchCriteriaId":"7C17C8F6-8C97-43D5-8ECE-7D9204F3C75D"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:o:schneider-electric:meg6260-0415:-:*:*:*:*:*:*:*","matchCriteriaId":"F93C8296-5845-498A-964A-D650F45B27B6"}]}]}],"references":[{"url":"https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-253-01","source":"cybersecurity@se.com","tags":["Vendor Advisory"]},{"url":"https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-253-01","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}