{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-19T01:56:39.819","vulnerabilities":[{"cve":{"id":"CVE-2019-6827","sourceIdentifier":"cybersecurity@se.com","published":"2019-07-15T21:15:10.883","lastModified":"2024-11-21T04:47:13.910","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A CWE-787: Out-of-bounds Write vulnerability exists in Interactive Graphical SCADA System (IGSS), Version 14 and prior, which could cause a software crash when data in the mdb database is manipulated."},{"lang":"es","value":"Una CWE-787: Existe una vulnerabilidad de escritura fuera de límites en Interactive Graphical SCADA System (IGSS), versión 14 y anteriores, que podría causar un bloqueo del software cuando son manipulados los datos en la base de datos mdb."}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","baseScore":6.8,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-787"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-787"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:interactive_graphical_scada_system:*:*:*:*:*:*:*:*","versionEndIncluding":"12.0","matchCriteriaId":"DA1E8EFC-6060-4BA0-95E5-81BBC3AF1353"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:interactive_graphical_scada_system:*:*:*:*:*:*:*:*","versionStartIncluding":"13.0","versionEndExcluding":"13.0.0.19140","matchCriteriaId":"01B21B69-BA94-4C71-842F-5F59F6F99FBC"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:interactive_graphical_scada_system:*:*:*:*:*:*:*:*","versionStartIncluding":"14.0","versionEndExcluding":"14.0.0.19120","matchCriteriaId":"DE3A6FED-3CD4-4088-BD09-5DB4F37C14E2"}]}]}],"references":[{"url":"https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-190-02","source":"cybersecurity@se.com","tags":["Vendor Advisory"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-19-671/","source":"cybersecurity@se.com","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://www.schneider-electric.com/ww/en/download/document/SEVD-2019-190-02","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-19-671/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]}]}}]}