{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-25T08:31:40.543","vulnerabilities":[{"cve":{"id":"CVE-2019-6816","sourceIdentifier":"cybersecurity@se.com","published":"2019-05-22T20:29:02.073","lastModified":"2024-11-21T04:47:12.880","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"In Modicon Quantum all firmware versions, a CWE-94: Code Injection vulnerability could cause an unauthorized firmware modification with possible Denial of Service when using Modbus protocol."},{"lang":"es","value":"En todas las versiones de firmware Modicon Quantum, una  CWE-94: Vulnerabilidad de Inyección de Código, podría generar una modificación de firmware no autorizada con una posible Denegación de Servicio al utilizar protocolo Modbus."}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H","baseScore":9.1,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.2}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:P/A:P","baseScore":6.4,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":10.0,"impactScore":4.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-94"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:modicon_quantum_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"745CC7A7-70FB-4551-8EBF-600B7A6236D7"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:modicon_quantum:-:*:*:*:*:*:*:*","matchCriteriaId":"A9B7CEF7-B9BA-4923-808F-DA2931569EBB"}]}]}],"references":[{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2019-134-09/","source":"cybersecurity@se.com","tags":["Vendor Advisory"]},{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2019-134-09/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}