{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-08-01T03:41:35.300","vulnerabilities":[{"cve":{"id":"CVE-2019-6814","sourceIdentifier":"cybersecurity@se.com","published":"2019-05-22T20:29:01.963","lastModified":"2026-06-17T02:39:43.773","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A CWE-287: Improper Authentication vulnerability exists in the NET55XX Encoder with firmware prior to version 2.1.9.7 which could cause impact to confidentiality, integrity, and availability when a remote attacker crafts a malicious request to the encoder webUI."},{"lang":"es","value":"CWE-287: Existe una vulnerabilidad de autenticación inadecuada en el codificador NET55XX con firmware anterior a la versión 2.1.9.7 que podría causar un impacto en la confidencialidad, integridad y disponibilidad cuando un atacante remoto realiza una solicitud maliciosa a la webUI del codificador"}],"affected":[{"source":"cybersecurity@se.com","affectedData":[{"vendor":"n/a","product":"ÊNET55XX Encoder with firmware prior to version 2.1.9.Ê","versions":[{"version":"ÊNET55XX Encoder with firmware prior to version 2.1.9.Ê","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","baseScore":7.5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"HIGH","exploitabilityScore":10.0,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-287"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-287"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:net5501_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.1.9.7","matchCriteriaId":"A3FC01AE-6A9A-41B7-AED5-C0FE4CDE0FDE"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:net5501:-:*:*:*:*:*:*:*","matchCriteriaId":"56CAC6D2-90C4-4BFD-AC1C-DE1FA2D97D6D"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:net5501-i_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.1.9.7","matchCriteriaId":"272F5867-C6BA-4B3B-9A7D-8AEFFF5CB78C"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:net5501-i:-:*:*:*:*:*:*:*","matchCriteriaId":"E5AC7E38-AC50-4921-904A-9396BA287EFB"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:net5501-xt_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.1.9.7","matchCriteriaId":"AC6B6743-5D3D-4178-A19F-975FBCC46FF5"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:net5501-xt:-:*:*:*:*:*:*:*","matchCriteriaId":"44A45E4C-7367-4FA6-98B6-FE3BD533A894"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:net5504_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.1.9.7","matchCriteriaId":"9B3ADFDE-F565-4F31-8AF4-6FC220C0A245"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:net5504:-:*:*:*:*:*:*:*","matchCriteriaId":"2BF4D959-932D-4A6C-A058-6841DC5DEE3B"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:net5500_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.1.9.7","matchCriteriaId":"1AEEC527-EC7F-44CA-9AF1-04638C85CD09"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:net5500:-:*:*:*:*:*:*:*","matchCriteriaId":"52FE10E6-80B0-4E11-B623-1BF13115B3BA"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:net5516_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.1.9.7","matchCriteriaId":"F52EBC2F-8E33-4481-AA8D-478273426BDB"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:net5516:-:*:*:*:*:*:*:*","matchCriteriaId":"817DD851-608A-42EF-AE9C-7FA23251B73E"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:net5508_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.1.9.7","matchCriteriaId":"346636DB-EF82-4886-A25C-5EFC7AC8FBE7"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:net5508:-:*:*:*:*:*:*:*","matchCriteriaId":"2245DB26-48EC-4617-B007-70477EE16611"}]}]}],"references":[{"url":"https://www.se.com/ww/en/download/document/SEVD-2019-134-01/","source":"cybersecurity@se.com","tags":["Vendor Advisory"]},{"url":"https://www.se.com/ww/en/download/document/SEVD-2019-134-01/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}