{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-10-01T18:21:56.819","vulnerabilities":[{"cve":{"id":"CVE-2019-6812","sourceIdentifier":"cybersecurity@se.com","published":"2019-05-22T20:29:01.933","lastModified":"2026-06-17T02:39:43.563","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A CWE-798 use of hardcoded credentials vulnerability exists in BMX-NOR-0200H with firmware versions prior to V1.7 IR 19 which could cause a confidentiality issue when using FTP protocol."},{"lang":"es","value":"Una CWE-798: Una vulnerabilidad de uso de credenciales codificadas en BMX-NOR-0200H con versiones de firmware anteriores a V1.7 IR 19, podría generar un problema de confidencialidad cuando se usa protocolo FTP."}],"affected":[{"source":"cybersecurity@se.com","affectedData":[{"vendor":"n/a","product":"Modicon RTU Module, BMX-NOR-0200H with firmware versions prior to V1.7 IR 19","versions":[{"version":"Modicon RTU Module, BMX-NOR-0200H with firmware versions prior to V1.7 IR 19","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","baseScore":7.2,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.2,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:P/I:N/A:N","baseScore":4.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":8.0,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-798"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-798"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:bmx-nor-0200h_firmware:1.7:ir17:*:*:*:*:*:*","matchCriteriaId":"4AC01C51-0353-4B7C-A127-432E4840CF15"},{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:bmx-nor-0200h_firmware:1.7:ir18:*:*:*:*:*:*","matchCriteriaId":"B711592B-3CA5-446E-BB55-2E79541EB02C"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:bmx-nor-0200h:-:*:*:*:*:*:*:*","matchCriteriaId":"B0A315A6-23AF-4F9C-886E-D87E100D865B"}]}]}],"references":[{"url":"https://security.cse.iitk.ac.in/responsible-disclosure","source":"cybersecurity@se.com","tags":["Third Party Advisory"]},{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2019-134-06/","source":"cybersecurity@se.com","tags":["Vendor Advisory"]},{"url":"https://security.cse.iitk.ac.in/responsible-disclosure","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"]},{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2019-134-06/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}