{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-09T00:13:11.969","vulnerabilities":[{"cve":{"id":"CVE-2019-6810","sourceIdentifier":"cybersecurity@se.com","published":"2019-09-17T20:15:11.860","lastModified":"2024-11-21T04:47:12.243","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"CWE-284: Improper Access Control vulnerability exists in BMXNOR0200H Ethernet / Serial RTU module (all firmware versions), which could cause the execution of commands by unauthorized users when using IEC 60870-5-104 protocol."},{"lang":"es","value":"CWE-284: Existe una vulnerabilidad de Control de Acceso Inapropiada en el módulo BMXNOR0200H Ethernet/Serial RTU (todas las versiones de firmware), lo que podría causar la ejecución de comandos por parte de usuarios no autorizados al utilizar el protocolo IEC 60870-5-104."}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:P/I:P/A:P","baseScore":6.5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.0,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-284"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"NVD-CWE-Other"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:bmxnor0200h_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"AECF5778-C5F5-4789-BD3D-793B35DDDBDF"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:bmxnor0200h:-:*:*:*:*:*:*:*","matchCriteriaId":"60D9A366-3394-4275-B884-AE6E7227156E"}]}]}],"references":[{"url":"https://security.cse.iitk.ac.in/responsible-disclosure","source":"cybersecurity@se.com","tags":["Third Party Advisory"]},{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2019-225-03/","source":"cybersecurity@se.com","tags":["Vendor Advisory"]},{"url":"https://security.cse.iitk.ac.in/responsible-disclosure","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"]},{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2019-225-03/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}