{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-22T14:29:59.666","vulnerabilities":[{"cve":{"id":"CVE-2019-6578","sourceIdentifier":"productcert@siemens.com","published":"2019-05-14T20:29:04.670","lastModified":"2024-11-21T04:46:44.410","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SINAMICS PERFECT HARMONY GH180 with NXG I control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G28), SINAMICS PERFECT HARMONY GH180 with NXG II control, MLFBs: 6SR2...-, 6SR3...-, 6SR4...- (All Versions with option G28). A denial of service vulnerability exists in the affected products. The vulnerability could be exploited by an attacker with network access to the device. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en SINAMICS PERFECT HARMONY GH180 con control NXG I, MLFBs: 6SR2 ...-, 6SR3 ...-, 6SR4 ...- (Todas las versiones con opción G28), SINAMICS PERFECT HARMONY GH180 con control NXG II , MLFBs: 6SR2 ...-, 6SR3 ...-, 6SR4 ...- (Todas las versiones con opción G28). Existe una vulnerabilidad de denegación de servicio en los productos afectados. La vulnerabilidad podría ser aprovechada por un atacante con acceso de red al dispositivo. El aprovechamiento exitoso no requiere privilegios ni interacción con el usuario. Un atacante podría usar la vulnerabilidad para comprometer la disponibilidad del sistema afectado. Hasta el momento de la publicación de  la asesoría, no se conocía aprovechamiento público de esta vulnerabilidad de seguridad."}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:N/A:P","baseScore":5.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":10.0,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-400"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-400"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:sinamics_perfect_harmony_gh180_with_nxg_i_control_mlfb_6sr2_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"8F7D94AC-ADFE-4806-A70D-464F118629FA"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:sinamics_perfect_harmony_gh180_with_nxg_i_control_mlfb_6sr2:-:*:*:*:*:*:*:*","matchCriteriaId":"DFA4A948-ED3E-49DA-A92E-234D7EA003FD"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:sinamics_perfect_harmony_gh180_with_nxg_i_control_mlfb_6sr3_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"CEA0F4E4-20A1-4F44-9A1F-5C3842BC8ADE"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:sinamics_perfect_harmony_gh180_with_nxg_i_control_mlfb_6sr3:-:*:*:*:*:*:*:*","matchCriteriaId":"212443C3-864C-4678-A553-26F099DF3C79"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:sinamics_perfect_harmony_gh180_with_nxg_i_control_mlfb_6sr4_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"8813393B-0092-4690-B01B-1263A6E428EA"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:sinamics_perfect_harmony_gh180_with_nxg_i_control_mlfb_6sr4:-:*:*:*:*:*:*:*","matchCriteriaId":"AF8446C2-86B4-4482-A740-283487E526FC"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:sinamics_perfect_harmony_gh180_with_nxg_ii_control_mlfb_6sr2_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"628653EC-C40B-42AC-92F2-04809F25B9A3"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:sinamics_perfect_harmony_gh180_with_nxg_ii_control_mlfb_6sr2:-:*:*:*:*:*:*:*","matchCriteriaId":"D7EA8969-4ACD-45D0-8AFD-2D7210120B51"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:sinamics_perfect_harmony_gh180_with_nxg_ii_control_mlfb_6sr3_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"D6375C30-9B48-47B7-96F2-F168370D8FFF"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:sinamics_perfect_harmony_gh180_with_nxg_ii_control_mlfb_6sr3:-:*:*:*:*:*:*:*","matchCriteriaId":"D2E32A7E-BCFB-422C-8690-43098D474D97"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:sinamics_perfect_harmony_gh180_with_nxg_ii_control_mlfb_6sr4_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"1ECD3079-A522-43CA-A10C-09931D80B2E1"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:sinamics_perfect_harmony_gh180_with_nxg_ii_control_mlfb_6sr4:-:*:*:*:*:*:*:*","matchCriteriaId":"14FB1B35-84C0-46FF-A802-4A06B213DB1F"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-606525.pdf","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-19-134-05","source":"productcert@siemens.com","tags":["Third Party Advisory","US Government Resource"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-606525.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-19-134-05","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"]}]}}]}