{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-15T20:24:21.485","vulnerabilities":[{"cve":{"id":"CVE-2019-6577","sourceIdentifier":"productcert@siemens.com","published":"2019-05-14T20:29:04.623","lastModified":"2024-11-21T04:46:44.267","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify particular parts of the device configuration via SNMP. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires system privileges and user interaction. An attacker could use the vulnerability to compromise confidentiality and the integrity of the affected system. At the stage of publishing this security advisory no public exploitation is known."},{"lang":"es","value":"Ha sido identificada una vulnerabilidad en SIMATIC HMI Comfort Panels 4\" - 22\" (Todas las versiones anteriores a la V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" & 15\" (Todas las versiones anteriores a la V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 y KTP900F (Todas las versiones anteriores a la V15.1 Update 1), SIMATIC WinCC Runtime Advanced (Todas las versiones anteriores a la V15.1 Update 1), SIMATIC WinCC Runtime Professional (Todas las versiones anteriores a la V15.1 Update 1), SIMATIC WinCC (TIA Portal) (Todas las versiones anteriores a la V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (Todas las versiones). El servidor web integrado podría permitir ataques de Cross-Site Scripting (XSS) si un atacante puede modificar partes particulares de la configuración del dispositivo por medio de SNMP. La vulnerabilidad de la seguridad podría ser explotada por un atacante con acceso de red al sistema afectado. La explotación con éxito requiere privilegios del sistema e interacción del usuario. Un atacante podría utilizar la vulnerabilidad para comprometer la confidencialidad y la integridad del sistema afectado. En la etapa de publicación de este aviso de seguridad no se conoce ninguna explotación pública."}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N","baseScore":5.4,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":2.3,"impactScore":2.7}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:S/C:N/I:P/A:N","baseScore":3.5,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"SINGLE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE"},"baseSeverity":"LOW","exploitabilityScore":6.8,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-80"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-79"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"15.1","matchCriteriaId":"865FD012-F390-4BB8-B14F-533840B95512"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*","matchCriteriaId":"3BCFE761-35C9-43EF-85BC-E8083B9F75CB"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:simatic_hmi_comfort_outdoor_panels_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"15.1","matchCriteriaId":"7299F88D-8885-4871-93E1-CBEFD3156B15"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_hmi_comfort_outdoor_panels:-:*:*:*:*:*:*:*","matchCriteriaId":"F4830E0D-0128-4E5B-AB81-2B238471AE4B"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"15.1","matchCriteriaId":"A8EC6926-258F-4F5C-88D2-33FE363340DB"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp400f:-:*:*:*:*:*:*:*","matchCriteriaId":"F106DEE3-4DED-46E4-9661-9D9C7B729BC0"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"15.1","matchCriteriaId":"2D9CF819-E06C-4EAA-85B3-AC40E039D485"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700:-:*:*:*:*:*:*:*","matchCriteriaId":"D175BC55-2EAA-4D4A-9E05-2FBB228160F1"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"15.1","matchCriteriaId":"B28FB484-526A-437E-80E3-B62F54F1BEF6"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp700f:-:*:*:*:*:*:*:*","matchCriteriaId":"5C39166C-38CA-426F-9702-B9CA5ED6630C"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"15.1","matchCriteriaId":"66FC2264-7DDD-4BEF-9795-AC6A5A00886B"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900:-:*:*:*:*:*:*:*","matchCriteriaId":"D29338CD-57BD-4734-9204-118EA53D42FB"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"15.1","matchCriteriaId":"8E4F0084-91A5-4D7E-971B-9DB979849594"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels_ktp900f:-:*:*:*:*:*:*:*","matchCriteriaId":"9E7858AB-F89E-4E50-8873-DE8F5F2A07CB"}]}]},{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):*:*:*:*:*:*:*:*","versionEndExcluding":"15.1","matchCriteriaId":"82389DAA-8D03-4806-AF86-87A1627A972F"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:advanced:*:*:*","versionEndExcluding":"15.1","matchCriteriaId":"C24C17B5-C379-4FD1-BA9F-38B2A329F254"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simatic_wincc_runtime:*:*:*:*:professional:*:*:*","versionEndExcluding":"15.1","matchCriteriaId":"24939BB3-7D99-4812-9EF8-65FE1FC9CCD8"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:simatic_hmi_tp_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"983886F3-5B11-4AC3-A4D9-C2816F9A37DF"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_hmi_tp:-:*:*:*:*:*:*:*","matchCriteriaId":"EE8F082D-04C4-4A3E-B3D1-6C2914C2917E"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:simatic_hmi_mp_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"A2271FBE-FF50-4614-A4A5-BBAB800F5FBD"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_hmi_mp:-:*:*:*:*:*:*:*","matchCriteriaId":"68C30B3C-90EF-4244-9235-D87A421850DC"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:simatic_hmi_op_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"217870AC-9EB0-4BDE-A2E2-381055B8E69C"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:simatic_hmi_op:-:*:*:*:*:*:*:*","matchCriteriaId":"A17F4CDF-5367-4343-AA1E-0C452495E598"}]}]}],"references":[{"url":"http://www.securityfocus.com/bid/108412","source":"productcert@siemens.com"},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"https://www.us-cert.gov/ics/advisories/ICSA-19-134-09","source":"productcert@siemens.com"},{"url":"http://www.securityfocus.com/bid/108412","source":"af854a3a-2127-422b-91ae-364da2661108"},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]},{"url":"https://www.us-cert.gov/ics/advisories/ICSA-19-134-09","source":"af854a3a-2127-422b-91ae-364da2661108"}]}}]}