{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-18T18:44:23.667","vulnerabilities":[{"cve":{"id":"CVE-2019-6567","sourceIdentifier":"productcert@siemens.com","published":"2019-06-12T14:29:04.820","lastModified":"2024-11-21T04:46:42.633","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All Versions < V5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3), SCALANCE X-414-3E (All versions). The affected devices store passwords in a recoverable format. An attacker may extract and recover device passwords from the device configuration. Successful exploitation requires access to a device configuration backup and impacts confidentiality of the stored passwords."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en la familia de switches SCALANCE X-200 (incluidas las variantes SIPLUS NET) (Todas las versiones anteriores a V5.2.4), familia de switches SCALANCE X-200IRT (incluidas las variantes SIPLUS NET) (Todas las versiones anteriores a V5.5.0), familia de switches SCALANCE X-300 (incluyendo X408 y las variantes SIPLUS NET) (Todas las versiones anteriores a V4.1.3), SCALANCE X-414-3E (Todas las versiones). Los dispositivos afectados almacenan contraseñas en un formato recuperable. Un atacante puede extraer y recuperar contraseñas de dispositivos desde la configuración del dispositivo. La explotación exitosa requiere acceso a una copia de seguridad de la configuración del dispositivo e impacta la confidencialidad de las contraseñas almacenadas. En el momento de la publicación del aviso no se conocía la explotación pública de esta vulnerabilidad de seguridad"}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N","baseScore":5.5,"baseSeverity":"MEDIUM","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":1.8,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:P/I:N/A:N","baseScore":2.1,"accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE"},"baseSeverity":"LOW","exploitabilityScore":3.9,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-257"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-522"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_x-200_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"5.2.4","matchCriteriaId":"443B5E7B-A491-4883-9853-A88D3B24E220"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_x-200:-:*:*:*:*:*:*:*","matchCriteriaId":"6FEF9F9F-4066-483B-BF95-3BA5625284DF"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_x-200irt_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"602CAF2E-2276-455C-82E5-A05BBFC198C5"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_x-200irt:-:*:*:*:*:*:*:*","matchCriteriaId":"94C7BE35-D3A6-488C-BB3D-D17D65DF4B80"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_x-300_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"3F2C50BB-CC63-40BE-A5F0-0F0C342586CA"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_x-300:-:*:*:*:*:*:*:*","matchCriteriaId":"B2D0AB50-6F0B-4232-8C8E-1647410D362D"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:scalance_x-414-3e_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"C9B3E06E-8822-406C-907A-40AE328B311C"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:scalance_x-414-3e:-:*:*:*:*:*:*:*","matchCriteriaId":"CE7762EE-1253-4A4B-81CF-1A6423135AB6"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-646841.pdf","source":"productcert@siemens.com","tags":["Patch","Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-646841.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]}]}}]}