{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-22T03:14:40.832","vulnerabilities":[{"cve":{"id":"CVE-2019-6536","sourceIdentifier":"ics-cert@hq.dhs.gov","published":"2019-03-27T16:29:00.780","lastModified":"2024-11-21T04:46:38.983","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Opening a specially crafted LCDS LAquis SCADA before 4.3.1.71 ELS file may result in a write past the end of an allocated buffer, which may allow an attacker to execute remote code in the context of the current process."},{"lang":"es","value":"Abrir un archivo ELS especialmente manipulado de LCDS LAquis SCADA, en versiones anteriores a la 4.3.1.71, podría resultar en una lectura más allá del final de un búfer asignado, lo que podría permitir que un atacante ejecute código remoto en el contexto del proceso actual."}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","baseScore":6.8,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-787"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-787"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:lcds:laquis_scada:4.1.0.4150:*:*:*:*:*:*:*","matchCriteriaId":"BA12D873-EB6A-4D64-BD12-8370ED063DDB"}]}]}],"references":[{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-19-073-01","source":"ics-cert@hq.dhs.gov","tags":["Third Party Advisory","US Government Resource"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-19-307/","source":"ics-cert@hq.dhs.gov"},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-19-073-01","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"]},{"url":"https://www.zerodayinitiative.com/advisories/ZDI-19-307/","source":"af854a3a-2127-422b-91ae-364da2661108"}]}}]}