{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-17T05:12:56.190","vulnerabilities":[{"cve":{"id":"CVE-2019-5589","sourceIdentifier":"psirt@fortinet.com","published":"2019-05-28T22:29:00.670","lastModified":"2024-11-21T04:45:11.217","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"An Unsafe Search Path vulnerability in FortiClient Online Installer (Windows version before 6.0.6) may allow an unauthenticated, remote attacker with control over the directory in which FortiClientOnlineInstaller.exe resides to execute arbitrary code on the system via uploading malicious .dll files in that directory."},{"lang":"es","value":"Una vulnerabilidad de ruta de búsqueda insegura en el instalador en línea de FortiClient (versión de Windows anterior a 6.0.6) puede permitir que un atacante remoto no identificado con control sobre el directorio en el que FortiClientOnlineInstaller.exe reside, ejecute código arbitrario en el sistema mediante la carga de archivos .dll maliciosos en este directorio."}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:C/I:C/A:C","baseScore":9.3,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":8.6,"impactScore":10.0,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-426"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:forticlient:*:*:*:*:*:windows:*:*","versionEndExcluding":"6.0.6","matchCriteriaId":"92AD53B0-B537-4A53-B8FC-2D7CC7EA8D9A"}]}]}],"references":[{"url":"https://fortiguard.com/advisory/FG-IR-19-060","source":"psirt@fortinet.com","tags":["Vendor Advisory"]},{"url":"https://fortiguard.com/advisory/FG-IR-19-060","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}