{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-22T00:07:42.694","vulnerabilities":[{"cve":{"id":"CVE-2019-3754","sourceIdentifier":"security_alert@emc.com","published":"2019-09-03T17:15:11.273","lastModified":"2024-11-21T04:42:28.160","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Dell EMC Unity Operating Environment versions prior to 5.0.0.0.5.116, Dell EMC UnityVSA versions prior to 5.0.0.0.5.116 and Dell EMC VNXe3200 versions prior to 3.1.10.9946299 contain a reflected cross-site scripting vulnerability on the cas/logout page. A remote unauthenticated attacker could potentially exploit this vulnerability by tricking a victim application user to supply malicious HTML or Java Script code to Unisphere, which is then reflected back to the victim and executed by the web browser."},{"lang":"es","value":"Dell EMC Unity Operating Environment en versiones anteriores a la 5.0.0.0.5.116, Dell EMC UnityVSA en versiones anteriores a la 5.0.0.0.5.116 y Dell EMC VNXe3200 en versiones anteriores a la 3.1.10.9946299 contienen una vulnerabilidad de Cross-Site Scripting (XSS) reflejado en la página cas/logout. Un atacante remoto no identificado podría potencialmente aprovechar esta vulnerabilidad engañando a un usuario de una aplicación víctima para que proporcione código HTML o JavaScript malicioso a Unisphere, que se devuelve a la víctima y es ejecutado por el navegador web."}],"metrics":{"cvssMetricV30":[{"source":"security_alert@emc.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:N/A:N","baseScore":4.7,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":1.4},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","baseScore":6.1,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":2.7}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:N/I:P/A:N","baseScore":4.3,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"security_alert@emc.com","type":"Secondary","description":[{"lang":"en","value":"CWE-79"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-79"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:dell:emc_unity_operating_environment:*:*:*:*:*:*:*:*","versionEndExcluding":"5.0.0.0.5.116","matchCriteriaId":"7091DD01-04E8-4560-BE2B-CC0F009C3D17"},{"vulnerable":true,"criteria":"cpe:2.3:a:dell:emc_unityvsa_operating_environment:*:*:*:*:*:*:*:*","versionEndExcluding":"5.0.0.0.5.116","matchCriteriaId":"DAC14A15-77F9-4E6F-B900-6D3FBA241999"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:dell:emc_vnxe3200_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"3.1.10.9946299","matchCriteriaId":"61312D56-931F-488B-9563-2E1CBAF6F686"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:dell:emc_vnxe3200:-:*:*:*:*:*:*:*","matchCriteriaId":"3E2FB19C-F28D-4D99-B965-85CEE552D981"}]}]}],"references":[{"url":"https://www.dell.com/support/security/en-us/details/536796/DSA-2019-125-Dell-EMC-Unity-and-VNXe3200-Family-Reflected-Cross-Site-Scripting-Vulnerability","source":"security_alert@emc.com","tags":["Vendor Advisory"]},{"url":"https://www.dell.com/support/security/en-us/details/536796/DSA-2019-125-Dell-EMC-Unity-and-VNXe3200-Family-Reflected-Cross-Site-Scripting-Vulnerability","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}