{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-23T20:21:32.456","vulnerabilities":[{"cve":{"id":"CVE-2019-20751","sourceIdentifier":"cve@mitre.org","published":"2020-04-16T21:15:13.067","lastModified":"2024-11-21T04:39:16.010","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D6100 before 1.0.0.60, DM200 before 1.0.0.61, EX2700 before 1.0.1.48, EX6100v2 before 1.0.1.76, EX6150v2 before 1.0.1.76, EX6200v2 before 1.0.1.72, EX8000 before 1.0.1.180, R7800 before 1.0.2.52, R8900 before 1.0.4.26, R9000 before 1.0.4.26, WN2000RPTv3 before 1.0.1.32, WN3000RPv2 before 1.0.0.68, WN3000RPv3 before 1.0.2.70, WN3100RPv2 before 1.0.0.66, WNDR4300v2 before 1.0.0.58, WNDR4500v3 before 1.0.0.58, and WNR2000v5 before 1.0.0.68."},{"lang":"es","value":"Determinados dispositivos NETGEAR están afectados por un desbordamiento del búfer en la región stack de la memoria por parte de un usuario autenticado. Esto afecta a D6100 versiones anteriores a 1.0.0.60, DM200 versiones anteriores a 1.0.0.61, EX2700 versiones anteriores a 1.0.1.48, EX6100v2 versiones anteriores a 1.0.1.76, EX6150v2 versiones anteriores a 1.0.1.76, EX6200v2 versiones anteriores a 1.0.1.72, EX8000 versiones anteriores a 1.0.1.180, R7800 versiones anteriores a 1.0.2.52, R8900 versiones anteriores a 1.0. 4.26, R9000 versiones anteriores a 1.0.4.26, WN2000RPTv3 versiones anteriores a 1.0.1.32, WN3000RPv2 versiones anteriores a 1.0.0.68, WN3000RPv3 versiones anteriores a 1.0.2.70, WN3100RPv2 versiones anteriores a 1.0.0.66, WNDR4300v2 versiones anteriores a 1.0.0.58, WNDR4500v3 versiones anteriores a 1.0.0.58, y WNR2000v5 versiones anteriores a 1.0.0.68."}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","baseScore":6.8,"baseSeverity":"MEDIUM","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":0.9,"impactScore":5.9}],"cvssMetricV30":[{"source":"cve@mitre.org","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","baseScore":6.8,"baseSeverity":"MEDIUM","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":0.9,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:A/AC:L/Au:S/C:P/I:P/A:P","baseScore":5.2,"accessVector":"ADJACENT_NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":5.1,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-787"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.0.60","matchCriteriaId":"FA3E7329-F839-4DD3-921F-B9E8DEDC8F12"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*","matchCriteriaId":"7EFD1E86-F100-4E46-935D-903EB6FEFE9D"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netgear:dm200_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.0.61","matchCriteriaId":"6B27650A-B7FE-41E4-8231-9283CC7B8349"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netgear:dm200:-:*:*:*:*:*:*:*","matchCriteriaId":"1B048F71-70F1-4D9F-84E2-9F7340F6ADAB"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.1.48","matchCriteriaId":"733650A8-D797-43B2-851E-1B364C9E7100"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*","matchCriteriaId":"5341B659-DE7D-43F1-954D-82049CBE18AD"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netgear:ex6100_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.1.76","matchCriteriaId":"CC89483B-6D99-4A1B-A513-B50EA44DA963"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netgear:ex6100:v2:*:*:*:*:*:*:*","matchCriteriaId":"88DD070C-7CBD-48A5-8D77-7C3D1C502D65"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.1.76","matchCriteriaId":"542F7529-27DB-41F1-A8E4-FA7A596E5DCC"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netgear:ex6150:v2:*:*:*:*:*:*:*","matchCriteriaId":"49846803-C6FB-4DD3-ADA7-78B9923536F2"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.1.72","matchCriteriaId":"3223C7E1-06DF-4CAA-89DD-611435165F49"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netgear:ex6200:v2:*:*:*:*:*:*:*","matchCriteriaId":"B4F62287-CB55-4FB1-AA39-62018654BA39"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netgear:ex8000_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.1.180","matchCriteriaId":"5F6F80A7-3B51-46FD-854E-D848F7906048"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netgear:ex8000:-:*:*:*:*:*:*:*","matchCriteriaId":"8D9781C9-799A-4BDA-A027-987627A01633"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.2.52","matchCriteriaId":"2C2195F1-18F6-4397-9D28-7A92003B7A76"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*","matchCriteriaId":"17CF7445-6950-45FE-9D1A-E23F63316329"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netgear:r8900_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.4.26","matchCriteriaId":"BEF7967B-5FA3-4D43-BEC5-2644FBB1D168"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netgear:r8900:-:*:*:*:*:*:*:*","matchCriteriaId":"0F859165-8D89-4CDD-9D48-9C7923D2261F"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.4.26","matchCriteriaId":"D34DD834-FE59-4F04-9448-FDC385CF70F6"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*","matchCriteriaId":"D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netgear:wn2000rpt_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.1.32","matchCriteriaId":"317AE6B1-BA33-49DF-A839-A49C5493996E"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netgear:wn2000rpt:v3:*:*:*:*:*:*:*","matchCriteriaId":"6FB1BE0D-E3CF-4C16-8C11-706B238E9934"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.0.68","matchCriteriaId":"663F925A-642C-4E4A-9D27-76B6EF6978F6"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netgear:wn3000rp:v2:*:*:*:*:*:*:*","matchCriteriaId":"3DAD97C7-458D-4547-82A4-EC7F4CFB2A90"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.2.70","matchCriteriaId":"DB6FCA6E-55DB-4D65-BD80-BF186C2F04FB"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*","matchCriteriaId":"AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.0.66","matchCriteriaId":"A480981E-57ED-47E3-B9AB-190E4783DC04"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*","matchCriteriaId":"4D8680F5-0C06-4CFC-8BA0-CF85D0438419"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.0.58","matchCriteriaId":"1DA490CC-DB27-4817-A589-61A0D221E9FD"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*","matchCriteriaId":"4428B145-B86D-4709-BBA9-64BDE7D35A25"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.0.58","matchCriteriaId":"652D8CA8-B56A-4403-B072-B4C245AB8EDA"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*","matchCriteriaId":"C31D6808-4103-4543-B7AB-84A79CD12006"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0.0.68","matchCriteriaId":"2D01DCF3-B6FD-4779-B048-DA4A963C9DEB"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*","matchCriteriaId":"317F25FF-B3A2-4C68-888F-D2627C564867"}]}]}],"references":[{"url":"https://kb.netgear.com/000060964/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Extenders-Gateways-and-Routers-PSV-2018-0171","source":"cve@mitre.org","tags":["Vendor Advisory"]},{"url":"https://kb.netgear.com/000060964/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Extenders-Gateways-and-Routers-PSV-2018-0171","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}