{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-09-29T14:53:01.169","vulnerabilities":[{"cve":{"id":"CVE-2019-19872","sourceIdentifier":"cve@mitre.org","published":"2020-11-27T15:15:11.530","lastModified":"2026-06-17T02:27:22.430","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"An issue was discovered in B&R Industrial Automation APROL before R4.2 V7.08. The AprolLoader could be used to inject and execute arbitrary unintended commands via an unspecified attack scenario, a different vulnerability than CVE-2019-16364."},{"lang":"es","value":"Se detectó un problema en B&amp;R Industrial Automation APROL versiones anteriores a R4.2 V7.08.&#xa0;AprolLoader podría ser usado para inyectar y ejecutar comandos arbitrarios no deseados por medio de un escenario de ataque no especificado, una vulnerabilidad diferente de CVE-2019-16364"}],"affected":[{"source":"cve@mitre.org","affectedData":[{"vendor":"n/a","product":"n/a","versions":[{"version":"n/a","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","baseScore":7.5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"HIGH","exploitabilityScore":10.0,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-77"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:br-automation:industrial_automation_aprol:*:*:*:*:*:*:*:*","versionEndExcluding":"r4.2","matchCriteriaId":"FBC9C267-2467-4EAC-9B99-52BA55757632"}]}]}],"references":[{"url":"https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf","source":"cve@mitre.org","tags":["Vendor Advisory"]},{"url":"https://www.br-automation.com/downloads_br_productcatalogue/BRP44400000000000000585952/APROL_R42_A1_ReleaseNotes_001.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}