{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-03T14:02:30.969","vulnerabilities":[{"cve":{"id":"CVE-2019-19292","sourceIdentifier":"productcert@siemens.com","published":"2020-03-10T20:15:19.243","lastModified":"2024-11-21T04:34:30.683","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The Control Center Server (CCS) contains an SQL injection\nvulnerability in its XML-based communication protocol as provided by default\non ports 5444/tcp and 5440/tcp.\nAn authenticated remote attacker could exploit this vulnerability to\nread or modify the CCS database and potentially execute administrative\ndatabase operations or operating system commands."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en Control Center Server (CCS) (Todas las versiones anteriores a V1.5.0). El Servidor de Control Center (CCS) contiene una vulnerabilidad de inyección SQL en su protocolo de comunicación basado en XML tal y como se proporciona por defecto en los puertos 5444/tcp y 5440/tcp. Un atacante remoto autenticado podría aprovechar esta vulnerabilidad para leer o modificar la base de datos del CCS y ejecutar potencialmente operaciones administrativas de la base de datos o comandos del sistema operativo"}],"metrics":{"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:P/I:P/A:P","baseScore":6.5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.0,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-89"}]},{"source":"nvd@nist.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-89"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:sinvr_3_central_control_server:*:*:*:*:*:*:*:*","matchCriteriaId":"16668E9A-2D0A-425E-87F4-18CFC50551D3"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:sinvr_3_video_server:*:*:*:*:*:*:*:*","matchCriteriaId":"0F21BB6D-BFE0-4B69-97F2-1A871A390B1E"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf","source":"productcert@siemens.com"},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf","source":"productcert@siemens.com","tags":["Mitigation","Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf","source":"af854a3a-2127-422b-91ae-364da2661108"},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Mitigation","Vendor Advisory"]}]}}]}