{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-10-01T17:22:27.438","vulnerabilities":[{"cve":{"id":"CVE-2019-18342","sourceIdentifier":"productcert@siemens.com","published":"2019-12-12T19:15:20.763","lastModified":"2026-06-17T02:24:52.383","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The SFTP service (default port 22/tcp) of the Control Center Server\n(CCS) does not properly limit its capabilities to the specified purpose.\n\nIn conjunction with CVE-2019-18341, an unauthenticated remote attacker with\nnetwork access to the CCS server could exploit this vulnerability\nto read or delete arbitrary files, or access other resources on the same\nserver."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en Control Center Server (CCS) (Todas las versiones anteriores a V1.5.0). El servicio SFTP (puerto predeterminado 22/tcp) del Servidor de Control Center (CCS) no limita adecuadamente sus capacidades al propósito especificado. Junto con CVE-2019-18341, un atacante remoto no autenticado con acceso a la red del servidor CCS podría explotar esta vulnerabilidad para leer o eliminar archivos arbitrarios, o acceder a otros recursos en el mismo servidor"}],"affected":[{"source":"productcert@siemens.com","affectedData":[{"vendor":"Siemens","product":"Control Center Server (CCS)","defaultStatus":"unknown","versions":[{"version":"All versions < V1.5.0","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H","baseScore":9.9,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.1,"impactScore":6.0},{"source":"nvd@nist.gov","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","baseScore":7.5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"HIGH","exploitabilityScore":10.0,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-749"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"NVD-CWE-Other"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:control_center_server:*:*:*:*:*:*:*:*","versionEndExcluding":"1.5.0","matchCriteriaId":"78E0586D-D26D-4362-BECA-73996052C3FE"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf","source":"productcert@siemens.com","tags":["Not Applicable","Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Not Applicable","Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}