{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-22T14:38:42.236","vulnerabilities":[{"cve":{"id":"CVE-2019-18250","sourceIdentifier":"ics-cert@hq.dhs.gov","published":"2019-11-26T00:15:11.780","lastModified":"2024-11-21T04:32:55.277","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"In all versions of ABB Power Generation Information Manager (PGIM) and Plant Connect, the affected product is vulnerable to authentication bypass, which may allow an attacker to remotely bypass authentication and extract credentials from the affected device."},{"lang":"es","value":"En todas las versiones de ABB Power Generation Information Manager (PGIM) y Plant Connect, el producto afectado es vulnerable a una omisión de autenticación, lo que puede permitir a un atacante omitir remotamente la autenticación y extraer credenciales del dispositivo afectado."}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","baseScore":7.5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"HIGH","exploitabilityScore":10.0,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-288"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-287"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:abb:plant_connect:*:*:*:*:*:*:*:*","matchCriteriaId":"2376DF85-21FD-4C6A-A9C1-B1E5FF276866"},{"vulnerable":true,"criteria":"cpe:2.3:a:abb:power_generation_information_manager:*:*:*:*:*:*:*:*","matchCriteriaId":"928D741D-5A9A-4EB9-827A-6DF53D7BBBD0"}]}]}],"references":[{"url":"https://www.us-cert.gov/ics/advisories/icsa-19-318-05","source":"ics-cert@hq.dhs.gov","tags":["Not Applicable","Permissions Required","Third Party Advisory","US Government Resource"]},{"url":"https://iotsecuritynews.com/abb-power-generation-information-manager-pgim-and-plant-connect/","source":"nvd@nist.gov","tags":["Third Party Advisory"]},{"url":"https://www.us-cert.gov/ics/advisories/icsa-19-318-05","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Not Applicable","Permissions Required","Third Party Advisory","US Government Resource"]}]}}]}