{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-02T20:56:20.955","vulnerabilities":[{"cve":{"id":"CVE-2019-15706","sourceIdentifier":"psirt@fortinet.com","published":"2025-03-17T14:15:15.107","lastModified":"2025-07-24T20:15:24.707","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"An improper neutralization of input during web page generation in the SSL VPN portal of FortiProxy version 2.0.0, version 1.2.9 and below and FortiOS version 6.2.1 and below, version 6.0.8 and below, version 5.6.12 may allow a remote authenticated attacker to perform a stored cross site scripting attack (XSS)."},{"lang":"es","value":"Una neutralización incorrecta de la entrada durante la generación de páginas web en el portal VPN SSL de FortiProxy versión 2.0.0, versión 1.2.9 y anteriores y FortiOS versión 6.2.1 y anteriores, versión 6.0.8 y anteriores, versión 5.6.12 puede permitir que un atacante autenticado remoto realice un ataque de cross site scripting (XSS) almacenado."}],"metrics":{"cvssMetricV31":[{"source":"psirt@fortinet.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:N/I:L/A:N","baseScore":4.1,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"NONE","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":2.3,"impactScore":1.4},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N","baseScore":5.4,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":2.3,"impactScore":2.7}]},"weaknesses":[{"source":"psirt@fortinet.com","type":"Secondary","description":[{"lang":"en","value":"CWE-79"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortiproxy:*:*:*:*:*:*:*:*","versionStartIncluding":"1.2.0","versionEndIncluding":"1.2.9","matchCriteriaId":"73F1E981-42BC-476D-B041-889BE6EF654F"},{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortiproxy:2.0.0:*:*:*:*:*:*:*","matchCriteriaId":"F3DD97EA-92AD-4EB1-B731-261F40BFC4BB"}]}]},{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*","versionStartIncluding":"5.6.0","versionEndExcluding":"5.6.13","matchCriteriaId":"ABFD64B3-F8CF-4E54-BF41-2098A28986D3"},{"vulnerable":true,"criteria":"cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*","versionStartIncluding":"6.0.0","versionEndExcluding":"6.0.9","matchCriteriaId":"C2F4F708-941B-4EBD-9DAB-D726887B63DF"},{"vulnerable":true,"criteria":"cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*","versionStartIncluding":"6.2.0","versionEndExcluding":"6.2.2","matchCriteriaId":"C41693AB-F242-42BC-91EE-70D4D0EC8B32"}]}]}],"references":[{"url":"https://fortiguard.fortinet.com/psirt/FG-IR-19-223","source":"psirt@fortinet.com","tags":["Vendor Advisory"]}]}}]}