{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-09-21T08:06:30.698","vulnerabilities":[{"cve":{"id":"CVE-2019-14919","sourceIdentifier":"cve@mitre.org","published":"2020-01-09T17:15:11.070","lastModified":"2026-06-17T02:19:19.203","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"An exposed Telnet Service on the Billion Smart Energy Router SG600R2 with firmware v3.02.rc6 allows a local network attacker to authenticate via hardcoded credentials into a shell, gaining root execution privileges over the device."},{"lang":"es","value":"Un Telnet Service expuesto en el Enrutador Billion Smart Energy SG600R2 con versión de firmware v3.02.rc6, permite a un atacante de red local autenticarse por medio de credenciales embebidas en un shell, alcanzando privilegios de ejecución root sobre el dispositivo."}],"affected":[{"source":"cve@mitre.org","affectedData":[{"vendor":"n/a","product":"n/a","versions":[{"version":"n/a","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:C/I:C/A:C","baseScore":7.2,"accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":3.9,"impactScore":10.0,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-798"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:billion:sg600_r2_firmware:3.02:rc6:*:*:*:*:*:*","matchCriteriaId":"19FE0329-68B9-4EE3-AA66-2CC9D0E58373"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:billion:sg600_r2:-:*:*:*:*:*:*:*","matchCriteriaId":"90D40018-3E57-4355-BB27-9FCB730639B1"}]}]}],"references":[{"url":"https://github.com/InnotecSystem/Device-Reversing/wiki/Firmware-Inspection","source":"cve@mitre.org","tags":["Exploit","Third Party Advisory"]},{"url":"https://github.com/InnotecSystem/Device-Reversing/wiki/Firmware-Inspection","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Exploit","Third Party Advisory"]}]}}]}