{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-11T17:05:10.069","vulnerabilities":[{"cve":{"id":"CVE-2019-13922","sourceIdentifier":"productcert@siemens.com","published":"2019-09-13T17:15:11.927","lastModified":"2024-11-21T04:25:42.320","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). An attacker with administrative privileges can obtain the hash of a connected device's password. The security vulnerability could be exploited by an attacker with network access to the SINEMA Remote Connect Server and administrative privileges. At the time of advisory publication no public exploitation of this security vulnerability was known."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en SINEMA Remote Connect Server (Todas las versiones anteriores a V2.0 SP1). Un atacante con privilegios administrativos puede obtener el hash de contraseña de un dispositivo conectado. La vulnerabilidad de seguridad podría ser explotada por un atacante con acceso de red al SINEMA Remote Connect Server y a privilegios administrativos. Al momento de la publicación de asesoramiento, no se conocía una explotación pública de esta vulnerabilidad de seguridad."}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N","baseScore":2.7,"baseSeverity":"LOW","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":1.2,"impactScore":1.4}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:P/I:N/A:N","baseScore":4.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":8.0,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-311"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-311"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*","versionEndIncluding":"2.0","matchCriteriaId":"380C606D-43A0-4362-9A5E-BC7320890196"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:sinema_remote_connect_server:2.0:hf1:*:*:*:*:*:*","matchCriteriaId":"33B706BB-C3D7-4BAA-A140-A7AF962F7141"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf","source":"productcert@siemens.com","tags":["Patch","Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]}]}}]}