{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-10T23:55:15.650","vulnerabilities":[{"cve":{"id":"CVE-2019-13920","sourceIdentifier":"productcert@siemens.com","published":"2019-09-13T17:15:11.867","lastModified":"2024-11-21T04:25:42.087","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). Some parts of the web application are not protected against Cross Site Request Forgery (CSRF) attacks. The security vulnerability could be exploited by an attacker that is able to trigger requests of a logged-in user to the application. The vulnerability could allow switching the connectivity state of a user or a device. At the time of advisory publication no public exploitation of this security vulnerability was known."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en SINEMA Remote Connect Server (Todas las versiones anteriores a V2.0 SP1). Algunas partes de la aplicación web no están protegidas contra ataques de tipo Cross Site Request Forgery (CSRF). La vulnerabilidad de seguridad podría ser explotada por un atacante que pueda desencadenar peticiones de un usuario registrado en la aplicación. La vulnerabilidad podría permitir cambiar el estado de conectividad de un usuario o dispositivo. Al momento de la publicación de asesoramiento, no se conocía una explotación pública de esta vulnerabilidad de seguridad."}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N","baseScore":4.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":1.4}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:N/I:P/A:N","baseScore":4.3,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-352"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-352"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*","versionEndIncluding":"2.0","matchCriteriaId":"380C606D-43A0-4362-9A5E-BC7320890196"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:sinema_remote_connect_server:2.0:hf1:*:*:*:*:*:*","matchCriteriaId":"33B706BB-C3D7-4BAA-A140-A7AF962F7141"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf","source":"productcert@siemens.com","tags":["Patch","Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-884497.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]}]}}]}