{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-18T14:05:00.493","vulnerabilities":[{"cve":{"id":"CVE-2019-10916","sourceIdentifier":"productcert@siemens.com","published":"2019-05-14T20:29:02.293","lastModified":"2024-11-21T04:20:08.653","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An attacker with access to the project file could run arbitrary system commands with the privileges of the local database server. The vulnerability could be exploited by an attacker with access to the project file. The vulnerability does impact the confidentiality, integrity, and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en SIMATIC PCS 7 V8.0 y versiones anteriores (Todas las versiones), SIMATIC PCS 7 V8.1 (Todas las versiones anteriores a la versión V8.1 con WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (Todas las versiones anteriores a la versión V8.2 SP1 con WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (Todas las versiones anteriores a la versión V9.0 SP2 con WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (Todas las versiones), SIMATIC WinCC (TIA Portal) V14 (Todas las versiones anteriores a la versión V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (Todas las versiones anteriores a la versión V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (Todas las versiones), SIMATIC WinCC Runtime Professional V14 ( Todas las versiones anteriores a la versión V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (Todas las versiones anteriores a la versión V15.1 Upd 3), SIMATIC WinCC V7.2 y anteriores (Todas las versiones), SIMATIC WinCC V7.3 (Todas las versiones anterior a la versión V7.3 Upd 19), SIMATIC WinCC V7.4 (Todas las versiones anteriores a la versión V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (Todas las versiones anteriores a la versión V7.5 Upd 3). Un atacante con acceso al archivo del proyecto podría ejecutar comandos arbitrarios del sistema con los privilegios del servidor de base de datos local. La vulnerabilidad podría ser explotada por un atacante con acceso al archivo del proyecto. La vulnerabilidad sí afecta la confidencialidad, integridad y disponibilidad del sistema afectado. En el momento de la publicación del aviso, no se conocía la explotación pública de esta vulnerabilidad de seguridad."}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C","baseScore":9.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":8.0,"impactScore":10.0,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-89"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-89"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*","versionEndIncluding":"8.0","matchCriteriaId":"78F045C4-8DC2-4FA8-833D-B430EA26F2A0"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simatic_pcs_7:8.1:*:*:*:*:*:*:*","matchCriteriaId":"858628AC-EA69-4D72-AE23-77A4A8DE2547"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simatic_pcs_7:8.2:*:*:*:*:*:*:*","matchCriteriaId":"F4A75F15-8F47-4348-A85C-D94BBA8F9992"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simatic_pcs_7:9.0:*:*:*:*:*:*:*","matchCriteriaId":"3F27A96F-58B7-492F-8CF7-DE04D4EDAAD8"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*","versionEndIncluding":"7.2","matchCriteriaId":"23B89914-E5BA-4670-B692-092AE9FFE148"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simatic_wincc:7.3:*:*:*:*:*:*:*","matchCriteriaId":"8D6229A2-9B8E-4F76-8425-589D2CE58B16"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simatic_wincc:7.4:*:*:*:*:*:*:*","matchCriteriaId":"F64B795A-7E66-49AE-BE40-E8EEAC12D280"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simatic_wincc:7.5:*:*:*:*:*:*:*","matchCriteriaId":"7D3A0BA7-EDC9-428D-A9C9-1CF602CEDFB5"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):13.0:*:*:*:*:*:*:*","matchCriteriaId":"E3D1A823-CE50-441F-B060-DA678DFE24FD"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):14.0:*:*:*:*:*:*:*","matchCriteriaId":"28A1BA01-7A92-4368-8A73-8FA47A08BC53"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simatic_wincc_\\(tia_portal\\):15.0:*:*:*:*:*:*:*","matchCriteriaId":"0256663E-3A97-4E99-995D-7446804DB496"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:simatic_wincc_runtime_professional:*:*:*:*:*:*:*:*","matchCriteriaId":"E07DBA91-379C-40F5-8C45-6EC302F5CA7D"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"https://www.us-cert.gov/ics/advisories/ICSA-19-134-08","source":"productcert@siemens.com","tags":["Third Party Advisory","US Government Resource"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]},{"url":"https://www.us-cert.gov/ics/advisories/ICSA-19-134-08","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"]}]}}]}