{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-09-22T21:58:42.926","vulnerabilities":[{"cve":{"id":"CVE-2018-8860","sourceIdentifier":"ics-cert@hq.dhs.gov","published":"2018-05-09T21:29:00.323","lastModified":"2026-06-17T02:05:32.010","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"In Vecna VGo Robot versions prior to 3.0.3.52164, an attacker may be able to capture firmware updates through the adjacent network."},{"lang":"es","value":"En las versiones anteriores a la 3.0.3.52164 de Vecna VGo Robot, un atacante podría capturar actualizaciones de firmware mediante la red adyacente."}],"affected":[{"source":"ics-cert@hq.dhs.gov","affectedData":[{"vendor":"ICS-CERT","product":"VGo Robot","versions":[{"version":"All versions prior to 3.0.3.52164","status":"affected"}]}]}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","baseScore":6.5,"baseSeverity":"MEDIUM","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:A/AC:L/Au:N/C:P/I:N/A:N","baseScore":3.3,"accessVector":"ADJACENT_NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE"},"baseSeverity":"LOW","exploitabilityScore":6.5,"impactScore":2.9,"acInsufInfo":true,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-200"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:vecna:vgo_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"3.0.3.52164","matchCriteriaId":"AD8DF500-4E04-4589-B73E-19CC592DA51F"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:vecna:vgo:-:*:*:*:*:*:*:*","matchCriteriaId":"A169276B-CA9C-44CC-9F3C-4969DD304520"}]}]}],"references":[{"url":"http://www.securityfocus.com/bid/103966","source":"ics-cert@hq.dhs.gov","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-114-01","source":"ics-cert@hq.dhs.gov","tags":["Third Party Advisory","US Government Resource"]},{"url":"http://www.securityfocus.com/bid/103966","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-114-01","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"]}]}}]}