{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-08-01T04:26:02.700","vulnerabilities":[{"cve":{"id":"CVE-2018-8846","sourceIdentifier":"ics-cert@hq.dhs.gov","published":"2018-09-26T19:29:01.363","lastModified":"2026-06-17T02:05:30.037","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is then served to other users."},{"lang":"es","value":"Philips e-Alert Unit (dispositivo no médico), versiones R2.1 y anteriores. El software no neutraliza (o lo hace incorrectamente) las entradas controlables por el usuario antes de colocarlas en las salidas que se emplean como página web y luego se sirven a otros usuarios."}],"affected":[{"source":"ics-cert@hq.dhs.gov","affectedData":[{"vendor":"Philips","product":"e-Alert Unit (non-medical device)","versions":[{"version":"R2.1 and prior","status":"affected"}]}]}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","baseScore":6.1,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":2.7}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:N/I:P/A:N","baseScore":4.3,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-79"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-79"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:philips:e-alert_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"r2.1","matchCriteriaId":"A20F1AAF-D947-4713-AB4E-12364592DBA3"}]}]}],"references":[{"url":"http://www.securityfocus.com/bid/105194","source":"ics-cert@hq.dhs.gov","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-242-01","source":"ics-cert@hq.dhs.gov","tags":["Mitigation","Third Party Advisory","US Government Resource"]},{"url":"https://www.usa.philips.com/healthcare/about/customer-support/product-security","source":"ics-cert@hq.dhs.gov","tags":["Vendor Advisory"]},{"url":"http://www.securityfocus.com/bid/105194","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-242-01","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Mitigation","Third Party Advisory","US Government Resource"]},{"url":"https://www.usa.philips.com/healthcare/about/customer-support/product-security","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}