{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-14T18:02:18.526","vulnerabilities":[{"cve":{"id":"CVE-2018-7842","sourceIdentifier":"cybersecurity@se.com","published":"2019-05-22T20:29:01.557","lastModified":"2024-11-21T04:12:51.697","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A CWE-290: Authentication Bypass by Spoofing vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause an elevation of privilege by conducting a brute force attack on Modbus parameters sent to the controller."},{"lang":"es","value":"CWE-290: Existe una vulnerabilidad de Omisión de Autenticación por suplantación de identidad en todas las versiones de Modicon M580, Modicon M340, Modicon Quantum y Modicon Premium, que podría generar una elevación de privilegios al realizar un ataque de fuerza bruta en los parámetros de Modbus enviados al controlador."}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1\/AV:N\/AC:L\/PR:N\/UI:N\/S:U\/C:H\/I:H\/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N\/AC:L\/Au:N\/C:P\/I:P\/A:P","baseScore":7.5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"HIGH","exploitabilityScore":10.0,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-290"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:modicon_m580_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"D52D735D-8AB5-40FE-A83F-266977601571"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:modicon_m580:-:*:*:*:*:*:*:*","matchCriteriaId":"E876C738-ABF6-4864-98A6-1E06E96A0DF4"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:modicon_m340_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"05CBA9AD-ECB7-453F-8551-DD176FDE8043"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:*","matchCriteriaId":"138681A2-0146-492B-8E10-06849FC27C6E"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:modicon_quantum_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"745CC7A7-70FB-4551-8EBF-600B7A6236D7"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:modicon_quantum:-:*:*:*:*:*:*:*","matchCriteriaId":"A9B7CEF7-B9BA-4923-808F-DA2931569EBB"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:modicon_premium_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"619CFD8D-9652-4AAB-AFC4-796B3F10F61F"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:modicon_premium:-:*:*:*:*:*:*:*","matchCriteriaId":"F00936E2-E6EF-4ABF-8666-7D83BE424F42"}]}]}],"references":[{"url":"https:\/\/www.schneider-electric.com\/en\/download\/document\/SEVD-2019-134-11\/","source":"cybersecurity@se.com","tags":["Vendor Advisory"]},{"url":"https:\/\/www.talosintelligence.com\/vulnerability_reports\/TALOS-2018-0741","source":"cybersecurity@se.com","tags":["Exploit","Third Party Advisory"]},{"url":"https:\/\/www.schneider-electric.com\/en\/download\/document\/SEVD-2019-134-11\/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]},{"url":"https:\/\/www.talosintelligence.com\/vulnerability_reports\/TALOS-2018-0741","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Exploit","Third Party Advisory"]}]}}]}