{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-27T20:51:27.296","vulnerabilities":[{"cve":{"id":"CVE-2018-7836","sourceIdentifier":"cybersecurity@se.com","published":"2018-12-24T16:29:00.937","lastModified":"2024-11-21T04:12:51.023","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"An unrestricted Upload of File with Dangerous Type vulnerability exists on numerous methods of the IIoT Monitor 3.1.38 software that could allow upload and execution of malicious files."},{"lang":"es","value":"Existe una vulnerabilidad de subida sin restricción de archivos con tipos peligrosos en numerosos métodos del software de IIoT Monitor 3.1.38 que podría permitir la subida y ejecución de archivos maliciosos."}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","baseScore":7.5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"HIGH","exploitabilityScore":10.0,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-434"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:iiot_monitor:3.1.38:*:*:*:*:*:*:*","matchCriteriaId":"9E622E71-AE37-4561-84CB-E5D2B4AE2674"}]}]}],"references":[{"url":"http://www.securityfocus.com/bid/106484","source":"cybersecurity@se.com","tags":["Third Party Advisory"]},{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-354-03/","source":"cybersecurity@se.com","tags":["Vendor Advisory"]},{"url":"http://www.securityfocus.com/bid/106484","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"]},{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-354-03/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}