{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-14T21:04:13.270","vulnerabilities":[{"cve":{"id":"CVE-2018-7834","sourceIdentifier":"cybersecurity@se.com","published":"2019-05-22T20:29:01.370","lastModified":"2024-11-21T04:12:50.817","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A CWE-79 Cross-Site Scripting vulnerability exists in all versions of the TSXETG100 allowing an attacker to send a specially crafted URL with an embedded script to a user that would then be executed within the context of that user."},{"lang":"es","value":"CWE-79: Existe una vulnerabilidad tipo Cross-Site Scripting en todas las versiones de TSXETG100, que permite a un atacante enviar una URL especialmente creada con un script integrado a un usuario que luego se ejecutaría dentro del contexto de ese usuario."}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0\/AV:N\/AC:L\/PR:N\/UI:R\/S:C\/C:L\/I:L\/A:N","baseScore":6.1,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":2.7}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N\/AC:M\/Au:N\/C:N\/I:P\/A:N","baseScore":4.3,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-79"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-79"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:tsxetg100_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"D7170E06-5CB1-477D-9782-D33CBDCB4AE2"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:tsxetg100:-:*:*:*:*:*:*:*","matchCriteriaId":"88088B4B-739E-4D57-BB1B-5067A527492D"}]}]}],"references":[{"url":"https:\/\/www.schneider-electric.com\/en\/download\/document\/SEVD-2019-134-07\/","source":"cybersecurity@se.com","tags":["Vendor Advisory"]},{"url":"https:\/\/www.schneider-electric.com\/en\/download\/document\/SEVD-2019-134-07\/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}