{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-21T12:39:50.165","vulnerabilities":[{"cve":{"id":"CVE-2018-7820","sourceIdentifier":"cybersecurity@se.com","published":"2019-09-17T20:15:11.000","lastModified":"2024-11-21T04:12:47.413","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A Credentials Management CWE-255 vulnerability exists in the APC UPS Network Management Card 2 AOS v6.5.6, which could cause Remote Monitoring Credentials to be viewed in plaintext when Remote Monitoring is enabled, and then disabled."},{"lang":"es","value":"Existe una vulnerabilidad CWE-255 de Administración de Credenciales en APC UPS Network Management Card 2 AOS versión v6.5.6, lo que podría causar que las Credenciales de Monitoreo Remoto sean visualizadas en texto plano cuando el Monitoreo Remoto está habilitado y luego deshabilitado."}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:N/A:N","baseScore":5.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":10.0,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-255"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-522"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:ap9630_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"6.7.2","matchCriteriaId":"789F5559-72FE-4620-A684-EF48D94FE0C0"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:ap9630:-:*:*:*:*:*:*:*","matchCriteriaId":"7F506A9E-D04C-4A29-B6E8-F88BFF7629E0"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:smart-ups_srt_5kva_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"6.7.2","matchCriteriaId":"03388B51-C023-4E2E-BE2F-1D73F461B105"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:smart-ups_srt_5kva:-:*:*:*:*:*:*:*","matchCriteriaId":"47BC2890-6BE7-4E5A-A751-BC60FF428EF3"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:ap9631_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"6.7.2","matchCriteriaId":"2DCE6A12-CEB8-400F-AD0D-95EEFBC58050"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:ap9631:-:*:*:*:*:*:*:*","matchCriteriaId":"096C4C31-4CAC-447D-8F49-12535035DCF7"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:ap9635_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"6.7.2","matchCriteriaId":"7D3D7DCD-6584-482A-BDFF-D22AC3DC841E"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:ap9635:-:*:*:*:*:*:*:*","matchCriteriaId":"A0AC4A1D-82AA-4836-B957-9CFF0DD22374"}]}]}],"references":[{"url":"https://www.apc.com/salestools/CCON-BFQMXC/CCON-BFQMXC_R0_EN.pdf","source":"cybersecurity@se.com","tags":["Vendor Advisory"]},{"url":"https://www.apc.com/salestools/CCON-BFQMXC/CCON-BFQMXC_R0_EN.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}