{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-22T16:02:31.616","vulnerabilities":[{"cve":{"id":"CVE-2018-7802","sourceIdentifier":"cybersecurity@se.com","published":"2018-12-24T16:29:00.827","lastModified":"2024-11-21T04:12:45.807","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A SQL Injection vulnerability exists in EVLink Parking, v3.2.0-12_v1 and earlier, which could give access to the web interface with full privileges."},{"lang":"es","value":"Existe una vulnerabilidad de inyección SQL en EVLink Parking, en versiones v3.2.0-12_v1 y anteriores, lo que podría otorgar acceso a la interfaz web con privilegios totales."}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:P/I:P/A:P","baseScore":6.5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.0,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-89"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:evlink_parking_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"3.2.0-12","matchCriteriaId":"FB8E9B41-C029-4370-B192-58617234E6AE"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:evlink_parking:-:*:*:*:*:*:*:*","matchCriteriaId":"C3A3C53B-06E7-4E10-B3DB-8319A0F8FCFD"}]}]}],"references":[{"url":"http://www.securityfocus.com/bid/106807","source":"cybersecurity@se.com","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-19-031-01","source":"cybersecurity@se.com","tags":["Mitigation","Third Party Advisory","US Government Resource"]},{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-354-01/","source":"cybersecurity@se.com","tags":["Patch","Vendor Advisory"]},{"url":"http://www.securityfocus.com/bid/106807","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-19-031-01","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Mitigation","Third Party Advisory","US Government Resource"]},{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-354-01/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]}]}}]}