{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-29T11:19:50.091","vulnerabilities":[{"cve":{"id":"CVE-2018-7799","sourceIdentifier":"cybersecurity@se.com","published":"2018-11-02T17:29:00.773","lastModified":"2024-11-21T04:12:45.457","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A DLL hijacking vulnerability exists in Schneider Electric Software Update (SESU), all versions prior to V2.2.0, which could allow an attacker to execute arbitrary code on the targeted system when placing a specific DLL file."},{"lang":"es","value":"Existe una vulnerabilidad de secuestro de DLL en Schneider Electric Software Update (SESU), en todas las versiones anteriores a la V2.2.0, lo que podría permitir que un atacante ejecutar código arbitrario en el sistema objetivo al colocar un archivo DLL específico."}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:C/I:C/A:C","baseScore":9.3,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":8.6,"impactScore":10.0,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-427"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:software_update_utility:*:*:*:*:*:*:*:*","versionEndExcluding":"2.2.0","matchCriteriaId":"C2ADF6DA-B0ED-4969-942E-A6A0182C4E3A"}]}]}],"references":[{"url":"http://www.securityfocus.com/bid/105951","source":"cybersecurity@se.com","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-305-02","source":"cybersecurity@se.com","tags":["Third Party Advisory","US Government Resource"]},{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-298-01/","source":"cybersecurity@se.com","tags":["Vendor Advisory"]},{"url":"http://www.securityfocus.com/bid/105951","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-305-02","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"]},{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-298-01/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}