{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-24T09:15:23.370","vulnerabilities":[{"cve":{"id":"CVE-2018-7787","sourceIdentifier":"cybersecurity@se.com","published":"2018-07-03T14:29:01.680","lastModified":"2024-11-21T04:12:44.083","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"In Schneider Electric U.motion Builder software versions prior to v1.3.4, this vulnerability is due to improper validation of input of context parameter in HTTP GET request."},{"lang":"es","value":"En el software de Schneider Electric U.motion Builder en versiones anteriores a la v1.3.4, esta vulnerabilidad se debe a la validación incorrecta de la entrada del parámetro context en la petición HTTP GET."}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","baseScore":5.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":3.9,"impactScore":1.4}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:N/A:N","baseScore":5.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":10.0,"impactScore":2.9,"acInsufInfo":true,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-20"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:u.motion_builder:*:*:*:*:*:*:*:*","versionEndExcluding":"1.3.4","matchCriteriaId":"D3DF1942-84D5-480C-96AA-3B03B58D43B5"}]}]}],"references":[{"url":"http://www.securityfocus.com/bid/104447","source":"cybersecurity@se.com","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/","source":"cybersecurity@se.com","tags":["Vendor Advisory"]},{"url":"http://www.securityfocus.com/bid/104447","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-151-01/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}