{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-04T04:13:08.727","vulnerabilities":[{"cve":{"id":"CVE-2018-7778","sourceIdentifier":"cybersecurity@se.com","published":"2018-07-03T14:29:01.210","lastModified":"2024-11-21T04:12:42.993","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"In Schneider Electric Evlink Charging Station versions prior to v3.2.0-12_v1, the Web Interface has an issue that may allow a remote attacker to gain administrative privileges without properly authenticating remote users."},{"lang":"es","value":"En las versiones anteriores a la v3.2.0-12_v1 de Schneider Electric Evlink Charging Station, la interfaz web tiene un problema que puede permitir que un atacante remoto obtenga privilegios administrativos sin autenticar correctamente a los usuarios remotos."}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","baseScore":7.5,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"HIGH","exploitabilityScore":10.0,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-306"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:evlink_charging_station_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"3.2.0-12_v1","matchCriteriaId":"0B2C5810-2436-4AE7-8B3E-5D28F91C098E"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:evlink_charging_station:-:*:*:*:*:*:*:*","matchCriteriaId":"D7BA4983-91EA-4E08-865E-1F4B3CCF28F8"}]}]}],"references":[{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-109-01/","source":"cybersecurity@se.com","tags":["Vendor Advisory"]},{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-109-01/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}