{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-23T18:53:18.286","vulnerabilities":[{"cve":{"id":"CVE-2018-7765","sourceIdentifier":"cybersecurity@se.com","published":"2018-07-03T14:29:00.617","lastModified":"2024-11-21T04:12:41.740","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"The vulnerability exists within processing of track_import_export.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the object_id input parameter."},{"lang":"es","value":"Existe una vulnerabilidad en el procesamiento de track_import_export.php en el software de Schneider Electric U.motion Builder en versiones anteriores a la v1.3.4. La consulta de la base de datos SQLite subyacente está sujeta a una inyección SQL en el parámetro de entrada object_id."}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","baseScore":6.8,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-89"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:u.motion_builder:*:*:*:*:*:*:*:*","versionEndExcluding":"1.3.4","matchCriteriaId":"D3DF1942-84D5-480C-96AA-3B03B58D43B5"}]}]}],"references":[{"url":"http://seclists.org/fulldisclosure/2019/May/26","source":"cybersecurity@se.com"},{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-095-01/","source":"cybersecurity@se.com","tags":["Vendor Advisory"]},{"url":"http://seclists.org/fulldisclosure/2019/May/26","source":"af854a3a-2127-422b-91ae-364da2661108"},{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-095-01/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}