{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-02T02:37:28.763","vulnerabilities":[{"cve":{"id":"CVE-2018-7239","sourceIdentifier":"cybersecurity@se.com","published":"2018-03-09T23:29:00.967","lastModified":"2024-11-21T04:11:51.273","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A DLL hijacking vulnerability exists in Schneider Electric's SoMove Software and associated DTM software components in all versions prior to 2.6.2 which could allow an attacker to execute arbitrary code."},{"lang":"es","value":"Existe una vulnerabilidad de secuestro de DLL en SoMove Software de Schneider Electric y en los componentes de software DTM asociados, en todas las versiones anteriores a la 2.6.2. Esto podría permitir que un atacante ejecute código arbitrario."}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","baseScore":6.8,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-426"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:atv_lift_dtm:*:*:*:*:*:*:*:*","versionEndExcluding":"12.7.0","matchCriteriaId":"8F0F8212-5CC6-4EB7-9F37-4587FC849A54"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:atv12_dtm:*:*:*:*:*:*:*:*","versionEndExcluding":"12.7.0","matchCriteriaId":"70DDF782-E80B-41A6-88F0-52D3BCCD0BE6"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:atv212_dtm:*:*:*:*:*:*:*:*","versionEndExcluding":"12.7.0","matchCriteriaId":"8A9E382F-DBB4-4B24-81C7-EE33B5248935"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:atv31_dtm:*:*:*:*:*:*:*:*","versionEndExcluding":"12.7.0","matchCriteriaId":"2429408E-48C9-4F97-A918-4DDECF6A7AB2"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:atv312_dtm:*:*:*:*:*:*:*:*","versionEndExcluding":"12.7.0","matchCriteriaId":"44D79762-E0D3-4DB9-8DD8-AE6A93953411"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:atv32_dtm:*:*:*:*:*:*:*:*","versionEndExcluding":"12.7.0","matchCriteriaId":"DC70CB2D-2AA8-40EC-97BC-0527D5F100ED"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:atv320_dtm:*:*:*:*:*:*:*:*","versionEndExcluding":"1.1.6","matchCriteriaId":"1D1862C8-5571-4DAC-B9F0-96DC3F2F846F"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:atv340_dtm:*:*:*:*:*:*:*:*","versionEndExcluding":"1.2.3","matchCriteriaId":"CB77B51C-CA0B-4C6E-91D2-41C450C6214E"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:atv600_dtm:*:*:*:*:*:*:*:*","versionEndExcluding":"1.8.0","matchCriteriaId":"FE8C39E7-A682-4453-945F-D1DFC9418A7C"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:atv61_dtm:*:*:*:*:*:*:*:*","versionEndExcluding":"12.7.0","matchCriteriaId":"988EB546-BB63-4DEF-800E-5C5A3C796163"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:atv71_dtm:*:*:*:*:*:*:*:*","versionEndExcluding":"12.7.0","matchCriteriaId":"848353C2-B49E-4B88-A57A-C783BF47C84C"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:atv900_dtm:*:*:*:*:*:*:*:*","versionEndExcluding":"1.3.5","matchCriteriaId":"3BA8B718-4947-41FE-9DDC-DA3AB85992B3"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:somove:*:*:*:*:*:*:*:*","versionEndExcluding":"2.6.2","matchCriteriaId":"AD8AD349-3536-4244-8D10-D860A5A7F1FF"}]}]}],"references":[{"url":"http://www.securityfocus.com/bid/103338","source":"cybersecurity@se.com","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02","source":"cybersecurity@se.com","tags":["Third Party Advisory","US Government Resource"]},{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/","source":"cybersecurity@se.com","tags":["Vendor Advisory"]},{"url":"http://www.securityfocus.com/bid/103338","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-065-02","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"]},{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2018-060-01/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}