{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-17T20:57:47.615","vulnerabilities":[{"cve":{"id":"CVE-2018-7108","sourceIdentifier":"security-alert@hpe.com","published":"2018-09-27T18:29:01.127","lastModified":"2024-11-21T04:11:39.360","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"HPE StorageWorks XP7 Automation Director (AutoDir) version 8.5.2-02 to earlier than 8.6.1-00 has a local and remote authentication bypass vulnerability that exposed the user authentication information of the storage system. This problem sometimes occurred under specific conditions when running a service template."},{"lang":"es","value":"HPE StorageWorks XP7 Automation Director (AutoDir) desde la versión 8.5.2-02 hasta antes de la 8.6.1-00 tiene una vulnerabilidad local y remota de omisión de autenticación que exponía la información de autenticación del usuario del sistema de almacenamiento. A veces, este problema ocurría en ciertas condiciones al ejecutar una plantilla de servicio."}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N","baseScore":5.9,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":2.2,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:N/A:N","baseScore":4.3,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-287"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:hpe:storageworks_xp7_automation_director:*:*:*:*:*:*:*:*","versionStartIncluding":"8.5.2-02","versionEndExcluding":"8.6.1-00","matchCriteriaId":"E048F4FF-1F0E-43ED-94E2-1B70CF017DC5"}]}]}],"references":[{"url":"http://www.securitytracker.com/id/1041696","source":"security-alert@hpe.com","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbst03879en_us","source":"security-alert@hpe.com","tags":["Vendor Advisory"]},{"url":"http://www.securitytracker.com/id/1041696","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US&docId=emr_na-hpesbst03879en_us","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}