{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-29T18:54:16.952","vulnerabilities":[{"cve":{"id":"CVE-2018-19029","sourceIdentifier":"ics-cert@hq.dhs.gov","published":"2019-02-05T18:29:00.820","lastModified":"2026-06-17T01:48:39.840","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"LCDS Laquis SCADA prior to version 4.1.0.4150 allows an attacker using a specially crafted project file to supply a pointer for a controlled memory address, which may allow remote code execution, data exfiltration, or cause a system crash."},{"lang":"es","value":"LCDS Laquis SCADA, en versiones anteriores a la 4.1.0.4150, permite a un atacante utilizar un archivo de proyecto especialmente manipulado para proporcionar un puntero para una dirección de memoria controlada, lo que podría permitir la ejecución remota de código, la exfiltración de datos o el cierre inesperado del sistema."}],"affected":[{"source":"ics-cert@hq.dhs.gov","affectedData":[{"vendor":"LCDS","product":"LCDS Laquis SCADA","versions":[{"version":"All versions prior to version 4.1.0.4150","status":"affected"}]}]}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:C","baseScore":8.3,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":8.6,"impactScore":8.5,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-822"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-476"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*","versionEndExcluding":"4.1.0.4150","matchCriteriaId":"A410DB6E-D5ED-411B-85EF-8445506E147A"}]}]}],"references":[{"url":"http://www.securityfocus.com/bid/106634","source":"ics-cert@hq.dhs.gov","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01","source":"ics-cert@hq.dhs.gov","tags":["Third Party Advisory","US Government Resource"]},{"url":"http://www.securityfocus.com/bid/106634","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"]}]}}]}