{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-17T19:43:59.665","vulnerabilities":[{"cve":{"id":"CVE-2018-18330","sourceIdentifier":"security@trendmicro.com","published":"2018-12-21T15:29:00.280","lastModified":"2024-11-21T03:55:43.630","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"An Address Bar Spoofing vulnerability in Trend Micro Dr. Safety for Android (Consumer) versions 3.0.1324 and below could allow an attacker to potentially trick a victim into visiting a malicious URL using address bar spoofing on the Private Browser of the app on vulnerable installations."},{"lang":"es","value":"Una vulnerabilidad de suplantación de la barra de direcciones en Trend Micro Dr. Safety for Android (Consumer), en versiones 3.0.1324 y anteriores, podría permitir que un atacante engañe a una víctima para que visite una URL maliciosa mediante la suplantación de la barra de direcciones en el navegador privado de la aplicación en instalaciones vulnerables."}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N","baseScore":6.5,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"HIGH","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:N/I:P/A:N","baseScore":4.3,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"NVD-CWE-noinfo"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:trendmicro:dr._safety:*:*:*:*:*:android:*:*","versionEndIncluding":"3.0.1324","matchCriteriaId":"8C8D7032-BD35-4E1A-8598-672A2A41F52A"}]}]}],"references":[{"url":"https://esupport.trendmicro.com/en-us/home/pages/technical-support/1121673.aspx","source":"security@trendmicro.com","tags":["Vendor Advisory"]},{"url":"https://esupport.trendmicro.com/en-us/home/pages/technical-support/1121673.aspx","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}