{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-09-23T01:05:43.609","vulnerabilities":[{"cve":{"id":"CVE-2018-17930","sourceIdentifier":"ics-cert@hq.dhs.gov","published":"2018-11-28T23:29:00.247","lastModified":"2026-06-17T01:46:33.283","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A stack-based buffer overflow vulnerability has been identified in Teledyne DALSA Sherlock Version 7.2.7.4 and prior, which may allow remote code execution."},{"lang":"es","value":"Se ha identificado una vulnerabilidad de desbordamiento de búfer basado en pila en Teledyne DALSA Sherlock, en versiones 7.2.7.4 y anteriores, lo que podría permitir la ejecución remota de código."}],"affected":[{"source":"ics-cert@hq.dhs.gov","affectedData":[{"vendor":"ICS-CERT","product":"Teledyne DALSA Sherlock","versions":[{"version":"Sherlock Version 7.2.7.4 and prior","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C","baseScore":10.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":10.0,"impactScore":10.0,"acInsufInfo":true,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-121"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-787"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:teledynedalsa:sherlock:*:*:*:*:*:*:*:*","versionEndIncluding":"7.2.7.4","matchCriteriaId":"DC31BB52-9ED7-4071-8529-4366396CDB40"}]}]}],"references":[{"url":"http://www.securityfocus.com/bid/105967","source":"ics-cert@hq.dhs.gov","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-324-01%2C","source":"ics-cert@hq.dhs.gov"},{"url":"https://www.teledynedalsa.com/en/products/imaging/vision-software/sherlock/","source":"ics-cert@hq.dhs.gov","tags":["Product","Vendor Advisory"]},{"url":"http://www.securityfocus.com/bid/105967","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-18-324-01%2C","source":"af854a3a-2127-422b-91ae-364da2661108"},{"url":"https://www.teledynedalsa.com/en/products/imaging/vision-software/sherlock/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Product","Vendor Advisory"]}]}}]}