{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-15T07:33:37.423","vulnerabilities":[{"cve":{"id":"CVE-2018-15722","sourceIdentifier":"vulnreport@tenable.com","published":"2018-12-20T21:29:00.727","lastModified":"2024-11-21T03:51:20.583","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"The Logitech Harmony Hub before version 4.15.206 is vulnerable to OS command injection via the time update request. A remote server or man in the middle can inject OS commands with a properly formatted response."},{"lang":"es","value":"Logitech Harmony Hub, en versiones anteriores a la 4.15.206, es vulnerable a una inyección de comandos del sistema operativo mediante la petición de actualización de tiempo. Un servidor remoto o Man-in-the-Middle (MitM) puede inyectar comandos del sistema operativo con una respuesta correctamente formateada."}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":8.1,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.2,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:C/I:C/A:C","baseScore":9.3,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":8.6,"impactScore":10.0,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"vulnreport@tenable.com","type":"Secondary","description":[{"lang":"en","value":"CWE-78"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-78"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:logitech:harmony_hub_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"4.15.206","matchCriteriaId":"B1A7B59C-D2E9-4A22-9BFC-1B51E310C2B7"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:logitech:harmony_hub:-:*:*:*:*:*:*:*","matchCriteriaId":"BDBF64B5-F971-4A8F-A76B-A5DF75D23DF5"}]}]}],"references":[{"url":"https://www.tenable.com/security/research/tra-2018-47","source":"vulnreport@tenable.com","tags":["Third Party Advisory"]},{"url":"https://www.tenable.com/security/research/tra-2018-47","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"]}]}}]}