{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-23T15:12:29.297","vulnerabilities":[{"cve":{"id":"CVE-2018-13809","sourceIdentifier":"productcert@siemens.com","published":"2019-04-17T14:29:02.840","lastModified":"2024-11-21T03:48:06.697","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in CP 1604 (All versions), CP 1616 (All versions). The integrated web server of the affected CP devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into following a malicious link. User interaction is required for a successful exploitation. At the time of advisory publication no public exploitation of this vulnerability was known."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en CP 1604 (todas las versiones), CP 1616 (todas las versiones). El servidor web integrado de los dispositivos CP afectados podría permitir ataques tipo Cross-Site Scripting (XSS) si se engaña a los usuarios desprevenidos para que sigan un enlace malicioso. La interacción del usuario es necesaria para una explotación con éxito. En el momento de la publicación consultiva, no se conocía la explotación pública de esta vulnerabilidad."}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","baseScore":6.1,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":2.7}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:N/I:P/A:N","baseScore":4.3,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"PARTIAL","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-79"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:cp_1604_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.8","matchCriteriaId":"6DC92E3A-CA37-4D08-A0EB-71DBB4C5395A"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:cp_1604:-:*:*:*:*:*:*:*","matchCriteriaId":"6148BD0D-5BD1-4182-8202-EBDB56B0D146"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:cp_1616_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.8","matchCriteriaId":"4D5FEC73-E96E-4945-8C0B-4A7B5B236ABD"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:cp_1616:-:*:*:*:*:*:*:*","matchCriteriaId":"1D7CC79A-1446-415F-8BFF-71C82C9256BB"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-559174.pdf","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-559174.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}