{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-23T22:10:38.509","vulnerabilities":[{"cve":{"id":"CVE-2018-13808","sourceIdentifier":"productcert@siemens.com","published":"2019-04-17T14:29:02.590","lastModified":"2024-11-21T03:48:06.507","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in CP 1604 (All versions), CP 1616 (All versions). An attacker with network access to port 23/tcp could extract internal communication data or cause a Denial-of-Service condition. Successful exploitation requires network access to a vulnerable device. At the time of advisory publication no public exploitation of this vulnerability was known."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en CP 1604 (todas las versiones), CP 1616 (todas las versiones). Un atacante con acceso de red al puerto 23/tcp podría extraer datos de comunicación interna o provocar una condición de denegación de servicio (DoS). La explotación con éxito requiere acceso de red a un dispositivo vulnerable. En el momento de la publicación consultiva, no se conocía públicamente la explotación de esta vulnerabilidad."}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H","baseScore":9.1,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.2}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:P/I:N/A:P","baseScore":6.4,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":10.0,"impactScore":4.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-200"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:cp_1604_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.8","matchCriteriaId":"6DC92E3A-CA37-4D08-A0EB-71DBB4C5395A"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:cp_1604:-:*:*:*:*:*:*:*","matchCriteriaId":"6148BD0D-5BD1-4182-8202-EBDB56B0D146"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:siemens:cp_1616_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"2.8","matchCriteriaId":"4D5FEC73-E96E-4945-8C0B-4A7B5B236ABD"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:siemens:cp_1616:-:*:*:*:*:*:*:*","matchCriteriaId":"1D7CC79A-1446-415F-8BFF-71C82C9256BB"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-559174.pdf","source":"productcert@siemens.com","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/pdf/ssa-559174.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}