{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-08-01T13:42:14.515","vulnerabilities":[{"cve":{"id":"CVE-2018-10626","sourceIdentifier":"ics-cert@hq.dhs.gov","published":"2018-08-10T18:29:00.353","lastModified":"2026-06-17T01:34:18.470","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Medtronic MyCareLink Patient Monitor’s update service does not sufficiently verify the authenticity of the data uploaded. An \nattacker who obtains per-product credentials from the monitor and paired\n implantable cardiac device information can potentially upload invalid \ndata to the Medtronic CareLink network."},{"lang":"es","value":"Se ha descubierto una vulnerabilidad en todas las versiones de Medtronic MyCareLink Patient Monitor 24950 y 24952. El servicio de actualización de los productos afectados no verifica lo suficiente la autenticidad de los datos subidos. Un atacante que obtenga las credenciales por producto del monitor y empareje información del dispositivo cardíaco implantable podría subir datos inválidos a la red de Medtronic CareLink."}],"affected":[{"source":"ics-cert@hq.dhs.gov","affectedData":[{"vendor":"Medtronic","product":"24950 MyCareLink Monitor","defaultStatus":"unaffected","versions":[{"version":"All versions","status":"affected"}]},{"vendor":"Medtronic","product":"24952 MyCareLink Monitor","defaultStatus":"unaffected","versions":[{"version":"All versions","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:N","baseScore":4.4,"baseSeverity":"MEDIUM","attackVector":"ADJACENT_NETWORK","attackComplexity":"HIGH","privilegesRequired":"LOW","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":1.3,"impactScore":2.7}],"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:A/AC:H/PR:L/UI:N/S:C/C:L/I:L/A:N","baseScore":4.4,"baseSeverity":"MEDIUM","attackVector":"ADJACENT_NETWORK","attackComplexity":"HIGH","privilegesRequired":"LOW","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":1.3,"impactScore":2.7}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:A/AC:M/Au:S/C:P/I:P/A:N","baseScore":3.8,"accessVector":"ADJACENT_NETWORK","accessComplexity":"MEDIUM","authentication":"SINGLE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"NONE"},"baseSeverity":"LOW","exploitabilityScore":4.4,"impactScore":4.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-345"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-345"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:medtronic:mycarelink_24952_patient_monitor_firmware:-:*:*:*:*:*:*:*","matchCriteriaId":"A4008DB3-E151-41BA-A308-7BE733268845"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:medtronic:mycarelink_24952_patient_monitor:-:*:*:*:*:*:*:*","matchCriteriaId":"60267DCC-89D0-48E3-B6EB-9AD60DC1F16F"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:medtronic:mycarelink_24950_patient_monitor_firmware:-:*:*:*:*:*:*:*","matchCriteriaId":"8AACDB33-1EC3-44E1-8C1C-38C766E85F85"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:medtronic:mycarelink_24950_patient_monitor:-:*:*:*:*:*:*:*","matchCriteriaId":"BCDA4070-6CDD-42CA-A4A8-DA6B0E98C64D"}]}]}],"references":[{"url":"http://www.securityfocus.com/bid/105042","source":"ics-cert@hq.dhs.gov","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2018/icsma-18-219-01.json","source":"ics-cert@hq.dhs.gov"},{"url":"https://global.medtronic.com/xg-en/product-security/security-bulletins/mycarelink-8-7-18.html","source":"ics-cert@hq.dhs.gov"},{"url":"https://www.cisa.gov/news-events/ics-medical-advisories/icsma-18-219-01","source":"ics-cert@hq.dhs.gov"},{"url":"http://www.securityfocus.com/bid/105042","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSMA-18-219-01","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"]}]}}]}