{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-08-01T05:22:36.319","vulnerabilities":[{"cve":{"id":"CVE-2018-10622","sourceIdentifier":"security@medtronic.com","published":"2018-08-10T18:29:00.230","lastModified":"2026-06-22T21:16:22.553","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. An attacker can use these credentials for network authentication."},{"lang":"es","value":"Se ha descubierto una vulnerabilidad en todas las versiones de Medtronic MyCareLink Patient Monitor 24950 y 24952. Los productos afectados emplean credenciales por producto que se almacenan en un formato recuperable. Un atacante puede emplear estas credenciales para autenticarse en red y cifrar datos locales en reposo."}],"affected":[{"source":"security@medtronic.com","affectedData":[{"vendor":"Medtronic","product":"24950 MyCareLink Monitor","defaultStatus":"unaffected","versions":[{"version":"0","lessThan":"February 25, 2026","versionType":"custom","status":"affected"}]},{"vendor":"Medtronic","product":"24952 MyCareLink Monitor","defaultStatus":"unaffected","versions":[{"version":"0","lessThan":"February 25, 2026","versionType":"custom","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"security@medtronic.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:N","baseScore":5.2,"baseSeverity":"MEDIUM","attackVector":"PHYSICAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"HIGH","availabilityImpact":"NONE"},"exploitabilityScore":0.9,"impactScore":4.2}],"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:P/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H","baseScore":7.1,"baseSeverity":"HIGH","attackVector":"PHYSICAL","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":0.5,"impactScore":6.0}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:L/AC:M/Au:N/C:P/I:N/A:N","baseScore":1.9,"accessVector":"LOCAL","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"NONE","availabilityImpact":"NONE"},"baseSeverity":"LOW","exploitabilityScore":3.4,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"security@medtronic.com","type":"Secondary","description":[{"lang":"en","value":"CWE-313"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-522"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:medtronic:mycarelink_24952_patient_monitor_firmware:-:*:*:*:*:*:*:*","matchCriteriaId":"A4008DB3-E151-41BA-A308-7BE733268845"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:medtronic:mycarelink_24952_patient_monitor:-:*:*:*:*:*:*:*","matchCriteriaId":"60267DCC-89D0-48E3-B6EB-9AD60DC1F16F"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:medtronic:mycarelink_24950_patient_monitor_firmware:-:*:*:*:*:*:*:*","matchCriteriaId":"8AACDB33-1EC3-44E1-8C1C-38C766E85F85"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:medtronic:mycarelink_24950_patient_monitor:-:*:*:*:*:*:*:*","matchCriteriaId":"BCDA4070-6CDD-42CA-A4A8-DA6B0E98C64D"}]}]}],"references":[{"url":"http://www.securityfocus.com/bid/105042","source":"security@medtronic.com","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2018/icsma-18-219-01.json","source":"security@medtronic.com"},{"url":"https://global.medtronic.com/xg-en/product-security/security-bulletins/mycarelink-8-7-18.html","source":"security@medtronic.com"},{"url":"https://www.cisa.gov/news-events/ics-medical-advisories/icsma-18-219-01","source":"security@medtronic.com"},{"url":"http://www.securityfocus.com/bid/105042","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSMA-18-219-01","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"]}]}}]}