{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-19T17:40:02.032","vulnerabilities":[{"cve":{"id":"CVE-2018-10512","sourceIdentifier":"security@trendmicro.com","published":"2018-08-15T19:29:00.480","lastModified":"2024-11-21T03:41:28.247","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability in Trend Micro Control Manager (versions 6.0 and 7.0) could allow an attacker to manipulate a reverse proxy .dll on vulnerable installations, which may lead to a denial of server (DoS)."},{"lang":"es","value":"Una vulnerabilidad en Trend Micro Control Manager (versiones 6.0 y 7.0) podría permitir que un atacante manipule un .dll proxy inverso en instalaciones vulnerables, lo que podría conducir a una denegación de servicio (DoS)."}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:N/A:P","baseScore":5.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":10.0,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"NVD-CWE-noinfo"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:trendmicro:control_manager:6.0:*:*:*:*:*:*:*","matchCriteriaId":"2F7E3779-69E4-46AB-94E3-4A81E35A5194"},{"vulnerable":true,"criteria":"cpe:2.3:a:trendmicro:control_manager:7.0:*:*:*:*:*:*:*","matchCriteriaId":"6F58BCC4-75BE-4B7D-8E29-27CAE3184858"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*","matchCriteriaId":"A2572D17-1DE6-457B-99CC-64AFD54487EA"}]}]}],"references":[{"url":"https://success.trendmicro.com/solution/1120112","source":"security@trendmicro.com","tags":["Mitigation","Patch","Vendor Advisory"]},{"url":"https://success.trendmicro.com/solution/1120112","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Mitigation","Patch","Vendor Advisory"]}]}}]}