{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-19T23:53:48.351","vulnerabilities":[{"cve":{"id":"CVE-2018-0350","sourceIdentifier":"psirt@cisco.com","published":"2018-07-18T23:29:00.633","lastModified":"2024-11-21T03:38:02.270","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability in the VPN subsystem configuration in the Cisco SD-WAN Solution could allow an authenticated, remote attacker to inject arbitrary commands that are executed with root privileges. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by authenticating to the device and submitting crafted input to the affected parameter in a web page. The attacker must be authenticated to access the affected parameter. A successful exploit could allow the attacker to execute commands with root privileges. This vulnerability affects the following Cisco products if they are running a release of the Cisco SD-WAN Solution prior to Release 18.3.0: vBond Orchestrator Software, vEdge 100 Series Routers, vEdge 1000 Series Routers, vEdge 2000 Series Routers, vEdge 5000 Series Routers, vEdge Cloud Router Platform, vManage Network Management Software, vSmart Controller Software. Cisco Bug IDs: CSCvi69808, CSCvi69810, CSCvi69814, CSCvi69822, CSCvi69827, CSCvi69828, CSCvi69836."},{"lang":"es","value":"Una vulnerabilidad en la configuración del subsistema VPN de Cisco SD-WAN Solution podría permitir que un atacante remoto autenticado inyecte comandos arbitrarios que se ejecutan con privilegios root. Esta vulnerabilidad se debe a una validación de entradas insuficiente. Un atacante podría explotar esta vulnerabilidad autenticándose en el dispositivo y enviando entradas manipuladas al parámetro afectado en una página web. El atacante debe estar autenticado para acceder al parámetro afectado. Su explotación con éxito podría permitir que el atacante ejecute comandos con privilegios root. Esta vulnerabilidad afecta a los siguientes productos Cisco si están ejecutando una versión de Cisco SD-WAN Solution anterior a la 18.3.0: vBond Orchestrator Software, vEdge 100 Series Routers, vEdge 1000 Series Routers, vEdge 2000 Series Routers, vEdge 5000 Series Routers, vEdge Cloud Router Platform, vManage Network Management Software y vSmart Controller Software. Cisco Bug IDs: CSCvi69808, CSCvi69810, CSCvi69814, CSCvi69822, CSCvi69827, CSCvi69828, CSCvi69836."}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C","baseScore":9.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"SINGLE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":8.0,"impactScore":10.0,"acInsufInfo":true,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"psirt@cisco.com","type":"Secondary","description":[{"lang":"en","value":"CWE-77"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-77"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:cisco:vbond_orchestrator:-:*:*:*:*:*:*:*","matchCriteriaId":"BA648664-0734-4D02-8944-CA4DF4D756D6"},{"vulnerable":true,"criteria":"cpe:2.3:a:cisco:vedge-plus:-:*:*:*:*:*:*:*","matchCriteriaId":"8828CED0-5B61-4BC9-B222-2295507E5FB7"},{"vulnerable":true,"criteria":"cpe:2.3:a:cisco:vedge-pro:-:*:*:*:*:*:*:*","matchCriteriaId":"937B8016-77E1-4F8C-8701-6AFFE36F6A49"},{"vulnerable":true,"criteria":"cpe:2.3:a:cisco:vmanage_network_management:-:*:*:*:*:*:*:*","matchCriteriaId":"DDF9528B-1D1E-4CF2-ABA8-D01CC6F4A8BD"},{"vulnerable":true,"criteria":"cpe:2.3:a:cisco:vsmart_controller:-:*:*:*:*:*:*:*","matchCriteriaId":"2F16884C-A2EE-4867-8806-6418E000078C"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:vedge-100_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"18.3.0","matchCriteriaId":"07BDB466-E5FC-40FF-8400-836551AD4AE5"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:vedge-100:-:*:*:*:*:*:*:*","matchCriteriaId":"5D71E4AF-6E91-4493-A591-4D056D0E59C1"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:vedge_100b_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"18.3.0","matchCriteriaId":"493ED5A7-3F08-4C2B-8259-F945088C42C4"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:vedge_100b:-:*:*:*:*:*:*:*","matchCriteriaId":"0811E0B5-889E-451E-B754-A8FEE32BDFA2"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:vedge_100m_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"18.3.0","matchCriteriaId":"7A89574B-5FA1-45D2-92F5-E6AE60B21AAC"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:vedge_100m:-:*:*:*:*:*:*:*","matchCriteriaId":"36973815-F46D-4ADA-B9DF-BCB70AC60BD3"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:vedge_100wm_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"18.3.0","matchCriteriaId":"A124EBDB-1E4D-44FF-8647-342ACB7FC536"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:vedge_100wm:-:*:*:*:*:*:*:*","matchCriteriaId":"061A302C-8D35-4E80-93DA-916DA7E90C06"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:vedge-1000_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"18.3.0","matchCriteriaId":"F33875D3-8A95-4201-B385-FA63CCDBE103"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:vedge-1000:-:*:*:*:*:*:*:*","matchCriteriaId":"F718A859-BCDB-4DD0-819D-60ABE710F0A9"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:vedge-2000_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"18.3.0","matchCriteriaId":"6D486E57-9E41-4744-AB0C-56B706B6989C"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:vedge-2000:-:*:*:*:*:*:*:*","matchCriteriaId":"52EEF288-492C-4CE6-A082-631005C5E711"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:cisco:vedge-5000_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"18.3.0","matchCriteriaId":"C78995CF-3005-496D-A168-F9EEF09EEF44"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:cisco:vedge-5000:-:*:*:*:*:*:*:*","matchCriteriaId":"C0C5E2C9-7D4B-405C-93DD-33DF265131E2"}]}]}],"references":[{"url":"http://www.securityfocus.com/bid/104874","source":"psirt@cisco.com","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180718-sdwan-cmdinj","source":"psirt@cisco.com","tags":["Vendor Advisory"]},{"url":"http://www.securityfocus.com/bid/104874","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180718-sdwan-cmdinj","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}