{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-29T10:44:09.332","vulnerabilities":[{"cve":{"id":"CVE-2017-9964","sourceIdentifier":"cybersecurity@se.com","published":"2018-01-02T03:29:00.267","lastModified":"2024-11-21T03:37:15.877","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A Path Traversal issue was discovered in Schneider Electric Pelco VideoXpert Enterprise all versions prior to 2.1. By sniffing communications, an unauthorized person can execute a directory traversal attack resulting in authentication bypass or session hijack."},{"lang":"es","value":"Se descubrió un problema de salto de directorio en todas las versiones anteriores a la 2.1 de Schneider Electric Pelco VideoXpert Enterprise. Al rastrear las comunicaciones, una persona no autorizada puede ejecutar un ataque de salto de directorio, resultando en una omisión de autenticación o de secuestro de sesión."}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:H/A:N","baseScore":6.9,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"HIGH","availabilityImpact":"NONE"},"exploitabilityScore":1.6,"impactScore":4.7}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:N","baseScore":5.8,"accessVector":"NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"NONE"},"baseSeverity":"MEDIUM","exploitabilityScore":8.6,"impactScore":4.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-22"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:pelco_videoxpert:*:*:*:*:enterprise:*:*:*","versionEndExcluding":"2.1","matchCriteriaId":"81B30BAF-370B-44F2-AB13-FFDFBB6F32F0"}]}]}],"references":[{"url":"http://www.securityfocus.com/bid/102338","source":"cybersecurity@se.com","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-355-02","source":"cybersecurity@se.com","tags":["Patch","Third Party Advisory","US Government Resource"]},{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2017-339-01/","source":"cybersecurity@se.com"},{"url":"http://www.securityfocus.com/bid/102338","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]},{"url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-355-02","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Third Party Advisory","US Government Resource"]},{"url":"https://www.schneider-electric.com/en/download/document/SEVD-2017-339-01/","source":"af854a3a-2127-422b-91ae-364da2661108"}]}}]}