{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-06T10:26:03.403","vulnerabilities":[{"cve":{"id":"CVE-2017-9958","sourceIdentifier":"cybersecurity@se.com","published":"2017-09-26T01:29:03.897","lastModified":"2025-04-20T01:37:25.860","vulnStatus":"Deferred","cveTags":[],"descriptions":[{"lang":"en","value":"An improper access control vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which an improper handling of the system configuration can allow an attacker to execute arbitrary code under the context of root."},{"lang":"es","value":"Existe una vulnerabilidad de control de acceso incorrecto en las versiones 1.2.1 y anteriores del software de U.motion Builder de Schneider Electric en el que una gestión incorrecta de la configuración del sistema puede permitir a un atacante ejecutar código arbitrario bajo el contexto de root."}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:L/AC:L/Au:N/C:C/I:C/A:C","baseScore":7.2,"accessVector":"LOCAL","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":3.9,"impactScore":10.0,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-732"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:u.motion_builder:*:*:*:*:*:*:*:*","versionEndIncluding":"1.2.1","matchCriteriaId":"849D3761-51AA-4820-B995-BBB065B8086B"}]}]}],"references":[{"url":"http://www.schneider-electric.com/en/download/document/SEVD-2017-178-01/","source":"cybersecurity@se.com","tags":["Vendor Advisory"]},{"url":"http://www.securityfocus.com/bid/99344","source":"cybersecurity@se.com","tags":["Third Party Advisory","VDB Entry"]},{"url":"http://www.schneider-electric.com/en/download/document/SEVD-2017-178-01/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]},{"url":"http://www.securityfocus.com/bid/99344","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"]}]}}]}